Original abstract
The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, non-trabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.
Czech abstract
Článek se zbývá výpočtovým modelováním interakce kostní tkáně s dentálními implantáty pro různou úroveň modelů spongiózní kosti.
English abstract
The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, non-trabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.
Keywords in Czech
Dentální impalntát; trámčitá kost; metoda konečných prvků; deformačně napěťová analýza, úroveň modelu
Keywords in English
Dental implant; trabecular bone; finite elements method; stress and strain analysis; modeling level
RIV year
2012
Released
07.03.2012
Location
Plzeň
ISSN
1802-680X
Volume
2011
Number
2
Pages from–to
173–186
Pages count
12
BIBTEX
@article{BUT73191,
author="Petr {Marcián} and Libor {Borák} and Zdeněk {Florian} and Sonia {Bartáková} and Ondřej {Konečný} and Petr {Navrátil},
title="Biomechanical study of the bone tissue with dental implants interaction",
year="2012",
volume="2011",
number="2",
month="March",
pages="173--186",
address="Plzeň",
issn="1802-680X"
}