Detail publikace
Biomechanická studie interakce kostní tkáně s dentálními implantáty
MARCIÁN, P. BORÁK, L. FLORIAN, Z. BARTÁKOVÁ, S. KONEČNÝ, O. NAVRÁTIL, P.
Český název
Biomechanická studie interakce kostní tkáně s dentálními implantáty
Anglický název
Biomechanical study of the bone tissue with dental implants interaction
Typ
článek v časopise - ostatní, Jost
Jazyk
en
Originální abstrakt
The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, non-trabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.
Český abstrakt
Článek se zbývá výpočtovým modelováním interakce kostní tkáně s dentálními implantáty pro různou úroveň modelů spongiózní kosti.
Anglický abstrakt
The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, non-trabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.
Klíčová slova česky
Dentální impalntát; trámčitá kost; metoda konečných prvků; deformačně napěťová analýza, úroveň modelu
Klíčová slova anglicky
Dental implant; trabecular bone; finite elements method; stress and strain analysis; modeling level
Rok RIV
2012
Vydáno
07.03.2012
Místo
Plzeň
ISSN
1802-680X
Ročník
2011
Číslo
2
Strany od–do
173–186
Počet stran
12
BIBTEX
@article{BUT73191,
author="Petr {Marcián} and Libor {Borák} and Zdeněk {Florian} and Sonia {Bartáková} and Ondřej {Konečný} and Petr {Navrátil},
title="Biomechanical study of the bone tissue with dental implants interaction",
year="2012",
volume="2011",
number="2",
month="March",
pages="173--186",
address="Plzeň",
issn="1802-680X"
}