Publication detail
Stress analysis of hip joint endoprosthesis ceramic head with real manufacturing inaccuracies consideration
FUIS, V.
Czech title
Napjatostní analýza v keramické hlavici kyčelní endoprotézy s uvažováním reálných výrobních nepřesností
English title
Stress analysis of hip joint endoprosthesis ceramic head with real manufacturing inaccuracies consideration
Type
conference paper
Language
cs
Original abstract
The paper presents the results of computational modeling of the stress states in the hip joint endoprosthesis ceramic head. The measured manufacturing inaccuracies of the contact areas of the head and the stem are covered in the model. Measuring device IMS UMPIRE was used to realize of the measuring of the deflections from the ideal cones. Loading of the considered model was in accordance with the norm ISO 7206-5, which is used to testing of the ceramic heads. System of FEM ANSYS was used to realize a computational modeling.
Czech abstract
The paper presents the results of computational modeling of the stress states in the hip joint endoprosthesis ceramic head. The measured manufacturing inaccuracies of the contact areas of the head and the stem are covered in the model. Measuring device IMS UMPIRE was used to realize of the measuring of the deflections from the ideal cones. Loading of the considered model was in accordance with the norm ISO 7206-5, which is used to testing of the ceramic heads. System of FEM ANSYS was used to realize a computational modeling.
English abstract
The paper presents the results of computational modeling of the stress states in the hip joint endoprosthesis ceramic head. The measured manufacturing inaccuracies of the contact areas of the head and the stem are covered in the model. Measuring device IMS UMPIRE was used to realize of the measuring of the deflections from the ideal cones. Loading of the considered model was in accordance with the norm ISO 7206-5, which is used to testing of the ceramic heads. System of FEM ANSYS was used to realize a computational modeling.
Keywords in English
Total hip joint endoprosthesis, computational modeling, finite element methods, manufacturing inaccuracies of contact areas.
Released
23.10.2002
Publisher
STU Bratislava
Location
Bratislava
ISBN
80-227-1783-5
Book
Mechanical Engineering 2002
Pages count
5
BIBTEX
@inproceedings{BUT5462,
author="Vladimír {Fuis},
title="Napjatostní analýza v keramické hlavici kyčelní endoprotézy s uvažováním reálných výrobních nepřesností",
booktitle="Mechanical Engineering 2002",
year="2002",
month="October",
publisher="STU Bratislava",
address="Bratislava",
isbn="80-227-1783-5"
}