Publication detail

One stage absorption cooling cycle with falling film smooth tube bundles

POSPÍŠIL, J. BALÁŠ, M. CHROBOCZEK, L. FORTELNÝ, Z.

Czech title

Jednostupňový absorpční oběh se skrápěným svazkem hladkých trubek

English title

One stage absorption cooling cycle with falling film smooth tube bundles

Type

conference paper

Language

en

Original abstract

The one-stage experimental absorption chiller with exactly same design of desorber-condenser and absorberevaporator was build up at the Brno University of Technology in 2008. This experimental absorption unit operates with LiBr H2O working pair. Design of the unit keeps two-cylinder conception, which is common for large-scale absorption units. Heat transfer between the working fluid and the heating/cooling water is realized with utilizing of falling film cooper pipe registers. Cooling capacity of the absorption chiller was designed 6 kW on temperature level 9 C. The contribution introduces the design of the 1 stage experimental absorption unit, building, operation experiences and results of carried out measurements. Measurement was focused on assessment of heat transfer on falling film tube bundles and entire COP evaluation. Four independent pumps enable test the influence of flow rate change in different loops of absorption unit.

Czech abstract

Jednostupňový experimentální absorpční chaldicí oběh se shodným provedením desorbéru-kondenzátoru a absorbéru-výparníku byl realizován na Vysokém učení technickém v roce 2008. Tento experimntální oběh pracuej s pracovní dvojicí LiBr-H2O. Návrh jednotky vychází z dvouválcové koncepce běžné pro velké absorpční jednotky. Přenos tepla mezi pracovní dvojicí a horkou a chladnou vodou je realizován skrápěnými registry měděnými trubek. Chaldicí výkon jednotky byl projektován 6 kW na teplotní hladině 9 sC. Příspěvek popisuje provedení oběhu, výrobu, provozní zkušenosti a výsledky realizovaných měření. Měření byla zaměřena na sledování přenosu tepal skrápěnými trubkovými svazky a hodnocení clekové efektivnosti zařízení. 4 nezávislá čerpadla umožňili testovat proměnlivý průtok pracovních médiií v různých smyčkách experimentálního zařízení.

English abstract

The one-stage experimental absorption chiller with exactly same design of desorber-condenser and absorberevaporator was build up at the Brno University of Technology in 2008. This experimental absorption unit operates with LiBr H2O working pair. Design of the unit keeps two-cylinder conception, which is common for large-scale absorption units. Heat transfer between the working fluid and the heating/cooling water is realized with utilizing of falling film cooper pipe registers. Cooling capacity of the absorption chiller was designed 6 kW on temperature level 9 C. The contribution introduces the design of the 1 stage experimental absorption unit, building, operation experiences and results of carried out measurements. Measurement was focused on assessment of heat transfer on falling film tube bundles and entire COP evaluation. Four independent pumps enable test the influence of flow rate change in different loops of absorption unit.

Keywords in Czech

absorpční jednotka, skrápění, přestup tepla, pracovní stabilizy, trubkový svazek

Keywords in English

absorption unit, falling film, heat transfer, working stability, tube bundle

RIV year

2009

Released

30.06.2009

Publisher

WSEAS

Location

Ateny, Řecko

ISBN

978-960-474-093-2

Book

Energy Problems and Environmental Engineering - Proceedings

Edition number

1

Pages from–to

358–362

Pages count

5

BIBTEX


@inproceedings{BUT31686,
  author="Jiří {Pospíšil} and Marek {Baláš} and Libor {Chroboczek} and Zdeněk {Fortelný},
  title="One stage absorption cooling cycle with falling film smooth tube bundles",
  booktitle="Energy Problems and Environmental Engineering - Proceedings",
  year="2009",
  month="June",
  pages="358--362",
  publisher="WSEAS",
  address="Ateny, Řecko",
  isbn="978-960-474-093-2"
}