Publication detail
Analysis of possibilities of elimination of liquid droplets from gas flow for mitigation of operating problems of gas preheater
PAČÍSKA, T. JEGLA, Z. REPPICH, M.
Czech title
Analýza možností eliminace kapalných podílů z proudu plynu za účelem zmírnění provozních problémů výměníku tepla
English title
Analysis of possibilities of elimination of liquid droplets from gas flow for mitigation of operating problems of gas preheater
Type
journal article - other
Language
en
Original abstract
This study deals with the analysis of possibilities of removing of undesirable sticky liquid droplets contained in process waste gas (PWG) stream before entering tubes of a tube bank heat exchanger (gas preheater), which is a part of gaseous wastes incineration unit. PWG is being preheated by high-temperature flue gas. Presence of the liquid droplets in the PWG in combination with the specific geometry of existing preheater containing stagnation zones on the entry to tube-side of preheater resulted to extensive fouling of tube-side of preheater by deposits. The aim of the study is to identify suitable way of removing liquid droplets from the PWG stream before preheater and to analyse possibilities of design of suitable separation equipment within the frame of spatial limitations and process and operating potential of the gaseous wastes incineration unit.
Czech abstract
Tato studie se zabývá analýzou možností odstranění nežádoucích lepkavých kapalných podílů obsažených v proudu procesního odplynu před vstupem do trubkového svazku výměníku tepla, který je součástí spalovací jednotky. Procesní odplyn je předehříván horkými spalinami. Přítomnost lepkavých kapalných podílů v proudu procesního odplynu, v kombinaci s nevhodnou geometrií mající za následek stagnační zóny na vstupu do trubkového prostoru daného výměníku, již vyústilo v rozsáhlé zanášení tohoto trubkového svazku. Cílem práce je nalézt vhodné řešení pro odstranění těchto lepkavých kapalných podílů z proudu procesního odplynu před vstupem do výměníku a analyzovat možnosti návrhu vhodného separačního zařízení při uvážení vlivu prostorových a technologických možností jednotky spalovny.
English abstract
This study deals with the analysis of possibilities of removing of undesirable sticky liquid droplets contained in process waste gas (PWG) stream before entering tubes of a tube bank heat exchanger (gas preheater), which is a part of gaseous wastes incineration unit. PWG is being preheated by high-temperature flue gas. Presence of the liquid droplets in the PWG in combination with the specific geometry of existing preheater containing stagnation zones on the entry to tube-side of preheater resulted to extensive fouling of tube-side of preheater by deposits. The aim of the study is to identify suitable way of removing liquid droplets from the PWG stream before preheater and to analyse possibilities of design of suitable separation equipment within the frame of spatial limitations and process and operating potential of the gaseous wastes incineration unit.
Keywords in Czech
Výměník tepla, kapalné podíly, zanášení
Keywords in English
Heat exchanger, liquid droplets, fouling
RIV year
2012
Released
25.08.2012
Publisher
AIDIC Servizi S.r.l.
Location
Milano, Italy
ISSN
1974-9791
Volume
29
Number
2
Pages from–to
1387–1392
Pages count
6
BIBTEX
@article{BUT93518,
author="Tomáš {Pačíska} and Zdeněk {Jegla} and Marcus {Reppich},
title="Analysis of possibilities of elimination of liquid droplets from gas flow for mitigation of operating problems of gas preheater",
year="2012",
volume="29",
number="2",
month="August",
pages="1387--1392",
publisher="AIDIC Servizi S.r.l.",
address="Milano, Italy",
issn="1974-9791"
}