Publication detail
Contamination Trials, summary.
RAUDENSKÝ, M. BOHÁČEK, J. BELLEROVÁ, H. HORÁK, A.
Czech title
Znečištění - testy
English title
Contamination Trials, summary.
Type
report
Language
en
Original abstract
The following experiments (Tab.1) were done on a new experimental testing bench developed in Brno. The experiments are divided in three groups according to the coolants: pure water, water diluted RM 192, and water diluted CaCl*2H2O + MgSO4*7H2O. Lechler full cone nozzle No. 460.844 (60 spray angle) was used and the initial temperature was 250 C. In the 2nd and 3rd group of experiments the concentration was increased step by step.
Czech abstract
Experimenty v rámci tohoto výzkumu byly provedené na testovacím zařizení vyvinutém v Laboratoři přenosu tepla a proudění v Brně. Byly rozděleny do 3 skupin podle typu chladiva: čistá voda, voda zředěná s RM 192 a voda zředěná s CaCl*2H2O + MgSO4*7H2O.
English abstract
The following experiments (Tab.1) were done on a new experimental testing bench developed in Brno. The experiments are divided in three groups according to the coolants: pure water, water diluted RM 192, and water diluted CaCl*2H2O + MgSO4*7H2O. Lechler full cone nozzle No. 460.844 (60 spray angle) was used and the initial temperature was 250 C. In the 2nd and 3rd group of experiments the concentration was increased step by step.
Keywords in English
contamination, coolant
Released
31.01.2007
Pages from–to
1–41
Pages count
41
BIBTEX
@techreport{BUT65026,
author="Miroslav {Raudenský} and Jan {Boháček} and Hana {Bellerová} and Aleš {Horák},
title="Contamination Trials, summary.",
year="2007",
month="January",
pages="1--41"
}