Publication detail

Unsuitable layout of alarm and trip system as a significant source of hazardous situations

KOTEK, L. TABAS, M.

Czech title

Nevhodné nastavení alarmového a ochranného systému jako významný zdroj nehod

English title

Unsuitable layout of alarm and trip system as a significant source of hazardous situations

Type

conference paper

Language

en

Original abstract

Human behaviour plays a key role in process industry safety. The possible actions that could be taken upon detecting an accident as well as how one reacts once they hear an alarm need to be considered. Many of major accidents were brought about by the alarm and trip system failure. Some of the most important accidents will be described in this contribution. Whenever risks are found to be unacceptable, solutions have to be found either by fundamental design changes or by providing protection measures and operators training. But the design of measurement, alarm and trip system should be appropriate to the premise or processes. Selection and evaluation of unsuitable scenarios can result in conservative designs that are not economical or designs with unacceptably high risks. The objective of this contribution is to consider the control room layout and measurement, alarm and trip system and propose risk reduction method of control room with alarm and trip systems orientation.

Czech abstract

Příspěvek se zabývá problemetikou nevhodného nastavení alarmového a ochranného systému, což představuje významný zdroj nehod. Článek na několika příkladech poukazuje na časté chyby a nastiňuje možnosti jeho využití jako nástroje managementu bezpečnosti.

English abstract

Human behaviour plays a key role in process industry safety. The possible actions that could be taken upon detecting an accident as well as how one reacts once they hear an alarm need to be considered. Many of major accidents were brought about by the alarm and trip system failure. Some of the most important accidents will be described in this contribution. Whenever risks are found to be unacceptable, solutions have to be found either by fundamental design changes or by providing protection measures and operators training. But the design of measurement, alarm and trip system should be appropriate to the premise or processes. Selection and evaluation of unsuitable scenarios can result in conservative designs that are not economical or designs with unacceptably high risks. The objective of this contribution is to consider the control room layout and measurement, alarm and trip system and propose risk reduction method of control room with alarm and trip systems orientation.

Keywords in Czech

alarmový a ochranný systém, HAZOP, bezpečnost v procesním průmyslu

Keywords in English

alarm and trip system, HAZOP, process industry safety

RIV year

2010

Released

01.01.2010

Publisher

ORGIS

Location

Praha

ISBN

978-80-02-02250-3

Book

CHISA 2010 ECCE 7, Summaries 5 - Systems and Technology

Pages from–to

1958–1958

Pages count

1

BIBTEX


@inproceedings{BUT34472,
  author="Luboš {Kotek} and Marek {Tabas},
  title="Unsuitable layout of alarm and trip system as a significant source of hazardous situations",
  booktitle="CHISA 2010 ECCE 7, Summaries 5 - Systems and Technology",
  year="2010",
  month="January",
  pages="1958--1958",
  publisher="ORGIS",
  address="Praha",