Publication detail

Influence of position of middle ear prosthesis on mechanics of hearing

DUŠEK, D. PELLANT, K.

Czech title

Influence of position of middle ear prosthesis on mechanics of hearing

English title

Influence of position of middle ear prosthesis on mechanics of hearing

Type

conference paper

Language

cs

Original abstract

Summary: The analysis of the mechanics of the normal middle ear and of the middle ear with ossicular prosthesis is performed. The creation of the finite element model of the middle ear is described. The model of the normal ear includes external ear canal, tympanic membrane, ossicle chain with joints to oval window in the enter of cochley. The model of prosthesis simulates T-like type of the commercial product. The amplitude of the stapes footplate velocity and the amplitude of pressure excitations in cochley were evaluated for different manners of prosthesis fixation.

Czech abstract

Summary: The analysis of the mechanics of the normal middle ear and of the middle ear with ossicular prosthesis is performed. The creation of the finite element model of the middle ear is described. The model of the normal ear includes external ear canal, tympanic membrane, ossicle chain with joints to oval window in the enter of cochley. The model of prosthesis simulates T-like type of the commercial product. The amplitude of the stapes footplate velocity and the amplitude of pressure excitations in cochley were evaluated for different manners of prosthesis fixation.

English abstract

Summary: The analysis of the mechanics of the normal middle ear and of the middle ear with ossicular prosthesis is performed. The creation of the finite element model of the middle ear is described. The model of the normal ear includes external ear canal, tympanic membrane, ossicle chain with joints to oval window in the enter of cochley. The model of prosthesis simulates T-like type of the commercial product. The amplitude of the stapes footplate velocity and the amplitude of pressure excitations in cochley were evaluated for different manners of prosthesis fixation.

Keywords in English

FEM model, harmonic analysis, human ear, prosthesis

RIV year

2006

Released

15.05.2006

Publisher

Akademie věd ČR

Location

Praha

ISBN

80-86246-27-2

Book

Engineering mechanics 2006

Pages count

2

BIBTEX


@inproceedings{BUT18764,
  author="Daniel {Dušek} and Karel {Pellant},
  title="Influence of position of middle ear prosthesis on mechanics of hearing",
  booktitle="Engineering mechanics 2006",
  year="2006",
  month="May",
  publisher="Akademie věd ČR",
  address="Praha",
  isbn="80-86246-27-2"
}