Publication detail
Determination of the Influence of Fuzzy Predictor Parameters in Lifetime Prediction of Insulating Material for Electrical Rotary Machines Windings
HAMMER, M. VAVRUŠKA, J. LATINA, P.
Czech title
Vliv parametrů fuzzy prediktoru na predikci zbytkové životnosti izolací elektrických strojů točivých.
English title
Determination of the Influence of Fuzzy Predictor Parameters in Lifetime Prediction of Insulating Material for Electrical Rotary Machines Windings
Type
conference paper
Language
en
Original abstract
The contribution deals with the life prediction of the Relanex insulating material which is used for the insulation of electrical rotary machines. With the help of the Sugeno type fuzzy controller, we determined the quantity of breakdown voltage and, on the basis of the breakdown voltage, we determined the actual state of the insulating material in the light of disruptive strength. According to the measured matrix of particular input quantities (Bv : activation energy of the conductive effect, Ba : activation energy of the polarization effect, Uk : critical voltage) and consequential training phase, we can predict critical voltage values Ups, compare those values with real breakdown voltage Up and do evaluation with the help of the absolute and relative errors.
Czech abstract
Příspěvek se zabývá predikcí životnosti izolačního materiálu Relanex pro vinutí elektrických točivých strojů. Pomocí veličin Bv, Ba, Uk a využitím fuzzy aparátu ve formě fuzzy prediktoru zjišťujeme velikost průrazného napětí, tím i aktuální stav izolačního materiálu z hlediska elektrické pevnosti a prognózu životnosti tohoto materiálu. K předpovědi velikosti průrazného napětí byl použit fuzzy prediktor typu Sugeno, zejména pro snadné nastavování vstupních parametrů. Dle naměřené matice hodnot jednotlivých vstupů (Bv, Ba, Uk, Up) a následné tréninkové fázi je možno předpovídat hodnoty kritického napětí Ups, které je možno dále porovnávat se skutečnými průraznými napětími Up a provádět vyhodnocování na základě relativních a absolutních chyb.
English abstract
The contribution deals with the life prediction of the Relanex insulating material which is used for the insulation of electrical rotary machines. With the help of the Sugeno type fuzzy controller, we determined the quantity of breakdown voltage and, on the basis of the breakdown voltage, we determined the actual state of the insulating material in the light of disruptive strength. According to the measured matrix of particular input quantities (Bv : activation energy of the conductive effect, Ba : activation energy of the polarization effect, Uk : critical voltage) and consequential training phase, we can predict critical voltage values Ups, compare those values with real breakdown voltage Up and do evaluation with the help of the absolute and relative errors.
Keywords in Czech
izolační materiál
Keywords in English
Insulating Material
Released
15.06.2004
Publisher
Hajnowka (Poland)
Location
Hajnowka (Poland)
ISBN
83-917944-4-X
Book
XL International Symposium on Electrical Machines SME2004
Pages count
4
BIBTEX
@inproceedings{BUT17282,
author="Miloš {Hammer} and Jiří {Vavruška} and Petr {Latina},
title="Determination of the Influence of Fuzzy Predictor Parameters in Lifetime Prediction of Insulating Material for Electrical Rotary Machines Windings",
booktitle="XL International Symposium on Electrical Machines SME2004",
year="2004",
month="June",
publisher="Hajnowka (Poland)",
address="Hajnowka (Poland)",
isbn="83-917944-4-X"
}