Publication detail

Axial check valve behaviour during flow reversal

HIMR, D. HABÁN, V. ZÁVORKA, D.

Czech title

Chování zpětného ventilu během změny orientace proudění

English title

Axial check valve behaviour during flow reversal

Type

conference paper

Language

en

Original abstract

An ideal check valve is supposed to have a zero pressure loss when the flow rate direction is positive and a negative flow rate is not possible. A real check valve has a low pressure loss and it is possible to suppress negative flow (especially when the check valve is new) under steady conditions. The transition between the steady positive flow and zero flow is often connected with a water hammer, here called check valve slam. An experimental investigation of behaviour of the axial check valve disc during the flow reversal is described in this paper. A high-speed camera was used for the disc position observation and pictures are compared with pressure pulsations and the flow rate.

Czech abstract

Ideální zpětný ventil má nulové tlakové ztráty při kladném směru proudění a nedovolí žádný zpěntý průtok. Skutečný zpětný ventil má nízké tlakové ztráty a zabrání zpětnému proudění (zejména pokud je nový) při statických podmínkách. Přechod mezi kladným průtokem a nulovým je často spojen s vodním rázem, zde nazývaným prásknutím zpětné armatury. V tomto článku je popsán experimentální výzkum chování disku zpětného ventilu během obracení směru proudění. Ke sledování polohy disku byla použita vysokorychlostní kamera a záznam byl porovnán s tlakovými pulzacemi a průtokem.

English abstract

An ideal check valve is supposed to have a zero pressure loss when the flow rate direction is positive and a negative flow rate is not possible. A real check valve has a low pressure loss and it is possible to suppress negative flow (especially when the check valve is new) under steady conditions. The transition between the steady positive flow and zero flow is often connected with a water hammer, here called check valve slam. An experimental investigation of behaviour of the axial check valve disc during the flow reversal is described in this paper. A high-speed camera was used for the disc position observation and pictures are compared with pressure pulsations and the flow rate.

Keywords in Czech

práskání zpětné armatury, vysokorychlostní kamera

Keywords in English

check valve slam, high-speed camera

Released

21.12.2019

ISSN

1755-1315

Book

IOP Conference Series: Earth and Environmental Science

Volume

405

Number

2019

Pages from–to

1–6

Pages count

6

BIBTEX


@inproceedings{BUT160952,
  author="Daniel {Himr} and Vladimír {Habán} and Dalibor {Závorka},
  title="Axial check valve behaviour during flow reversal",
  booktitle="IOP Conference Series: Earth and Environmental Science",
  year="2019",
  volume="405",
  number="2019",
  month="December",
  pages="1--6",
  issn="1755-1315"
}