Influence of response time of magnetorheological valve in Skyhook controlled three-parameter damping system
STRECKER, Z. ROUPEC, J. MAZŮREK, I. MACHÁČEK, O. KUBÍK, M.
English title
Influence of response time of magnetorheological valve in Skyhook controlled three-parameter damping system
Type
journal article in Web of Science
Language
en
Original abstract
A three-parameter suspension system is often used for vibration isolation of sensitive devices especially in a space industry. This article describes the three-parameter suspension system with magnetorheological valve controlled by Skyhook algorithm. Simulations of such systems showed promising results. They, however, showed that the suspension performance is strongly influenced by magnetorheological valve response time. Results from simulations proved that the semiactive control of such system with response time of magnetorheological damper up to 4 ms outperforms any passive setting. The simulations were verified by an experiment on suspension system with magnetorheological valve with response time between 3.5 and 4.1 ms controlled by a Skyhook algorithm. Although the control algorithm was slightly modified in order to prevent instabilities of control loop caused by signal noise, the results from the experiment showed the same trends like the simulations.
English abstract
A three-parameter suspension system is often used for vibration isolation of sensitive devices especially in a space industry. This article describes the three-parameter suspension system with magnetorheological valve controlled by Skyhook algorithm. Simulations of such systems showed promising results. They, however, showed that the suspension performance is strongly influenced by magnetorheological valve response time. Results from simulations proved that the semiactive control of such system with response time of magnetorheological damper up to 4 ms outperforms any passive setting. The simulations were verified by an experiment on suspension system with magnetorheological valve with response time between 3.5 and 4.1 ms controlled by a Skyhook algorithm. Although the control algorithm was slightly modified in order to prevent instabilities of control loop caused by signal noise, the results from the experiment showed the same trends like the simulations.
Keywords in English
Magnetorheological valve, three-parameter system, fast response, Skyhook, semiactive damping
Released
16.11.2018
Publisher
SAGE Publications
ISSN
1687-8140
Volume
10
Number
11
Pages from–to
1–8
Pages count
8
BIBTEX
@article{BUT151733,
author="Zbyněk {Strecker} and Jakub {Roupec} and Ivan {Mazůrek} and Ondřej {Macháček} and Michal {Kubík},
title="Influence of response time of magnetorheological valve in Skyhook controlled three-parameter damping system",
year="2018",
volume="10",
number="11",
month="November",
pages="1--8",
publisher="SAGE Publications",
issn="1687-8140"
}