Publication detail

A novel method for measurement of MR fluid sedimentation and its experimental verification

ROUPEC, J. BERKA, P. MAZŮREK, I. STRECKER, Z. KUBÍK, M. MACHÁČEK, O. ANDANI, M. Taheri

English title

A novel method for measurement of MR fluid sedimentation and its experimental verification

Type

journal article in Web of Science

Language

en

Original abstract

This article presents a novel sedimentation measurement technique based on quantifying the changes in magnetic flux density when the magnetorheological fluid (MRF) passes through the air gap of the magnetic circuit. The sedimented MRF appears to have as a result of increased iron content. Accordingly, the sedimented portion of the sample displays a higher magnetic conductivity than the unsedimented area that contains less iron particles. The data analysis and evaluation methodology is elaborated along with an example set of measurements, which are compared against the visual observations and available data in the literature. Experiments indicate that unlike the existing methods, the new technique is able to accurately generate the complete curves of the sedimentation profile in a long-term sedimentation. The proposed method is capable of successfully detecting the area with the tightest particle configuration near the bottom ('cake' layer). It also addresses the issues with the development of an unclear boundary between the carrier fluid and the sediment (mudline) during an accelerated sedimentation process; improves the sensitivity of the sedimentation detection and accurately measure the changes in particle concentration with a high resolution.

English abstract

This article presents a novel sedimentation measurement technique based on quantifying the changes in magnetic flux density when the magnetorheological fluid (MRF) passes through the air gap of the magnetic circuit. The sedimented MRF appears to have as a result of increased iron content. Accordingly, the sedimented portion of the sample displays a higher magnetic conductivity than the unsedimented area that contains less iron particles. The data analysis and evaluation methodology is elaborated along with an example set of measurements, which are compared against the visual observations and available data in the literature. Experiments indicate that unlike the existing methods, the new technique is able to accurately generate the complete curves of the sedimentation profile in a long-term sedimentation. The proposed method is capable of successfully detecting the area with the tightest particle configuration near the bottom ('cake' layer). It also addresses the issues with the development of an unclear boundary between the carrier fluid and the sediment (mudline) during an accelerated sedimentation process; improves the sensitivity of the sedimentation detection and accurately measure the changes in particle concentration with a high resolution.

Keywords in English

magnetorheological fluid; MR fluid; sedimentation; profile of sedimentation; novel method

Released

01.10.2017

Publisher

IOP PUBLISHING LTD, TEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND

Location

Bristol

ISSN

0964-1726

Volume

26

Number

10

Pages from–to

1–13

Pages count

13

BIBTEX


@article{BUT139411,
  author="Jakub {Roupec} and Pavel {Berka} and Ivan {Mazůrek} and Zbyněk {Strecker} and Michal {Kubík} and Ondřej {Macháček},
  title="A novel method for measurement of MR fluid sedimentation and its experimental verification ",
  year="2017",
  volume="26",
  number="10",
  month="October",
  pages="1--13",
  publisher="IOP PUBLISHING LTD, TEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND ",
  address="Bristol",
  issn="0964-1726"
}