Publication detail

Two-dimensional correction of data measured using a large pressure sensor

POHANKA, M.

Czech title

Dvou rozměrová korekce naměřených dat s použitím tlakového čidla

English title

Two-dimensional correction of data measured using a large pressure sensor

Type

conference paper

Language

en

Original abstract

This paper describes how to obtain precise results using a real finite.size pressure sensor. In some cases, the impact distribution is very small or at least very narrow. Measuring such distributions with a pressure sensor, which is not small enough, results in incorrect data. The pressure is being averaged during the measurement and the shape of the obtained spray distribution is larger and the measured pressure maximum is lower than the real one. This paper describes how to correct the measured spray distribution. A two-dimensional fast Fourier Transformation (FFT) is used to convert both the measured data and pressure sensor to the frquency domain. The correction of the measured spray distribution is done in the frequency domain and then an inverse two-dimensional FFT is used to convert the data back to the space domain. This allows suppressing noise in the measured data that would be extremely amplified. Very good results are presented using both the artificial and real data.

Czech abstract

Tento článek popisuje,jak obdržet přesné hodnoty s použitím tlakového sensoru a jak opravit měřené hodnoty rozložení ostřiku. Dvou rozměrná FFT Fast Fourier Transformation – Fourierova transformace je použita k přepočtení naměřených dat a tlakového čidla na kmitočtovou doménu. Korekce měřeného rozložení ostřiku je provedena v kmitočtové doméně a poté je inverzní dvou rozměrná FFT použita pro přepočet dat zpět do prostorové domény

English abstract

This paper describes how to obtain precise results using a real finite.size pressure sensor. In some cases, the impact distribution is very small or at least very narrow. Measuring such distributions with a pressure sensor, which is not small enough, results in incorrect data. The pressure is being averaged during the measurement and the shape of the obtained spray distribution is larger and the measured pressure maximum is lower than the real one. This paper describes how to correct the measured spray distribution. A two-dimensional fast Fourier Transformation (FFT) is used to convert both the measured data and pressure sensor to the frquency domain. The correction of the measured spray distribution is done in the frequency domain and then an inverse two-dimensional FFT is used to convert the data back to the space domain. This allows suppressing noise in the measured data that would be extremely amplified. Very good results are presented using both the artificial and real data.

Keywords in Czech

tlakové čidlo, dvou rozměrová korekce, frekvenční doména

Keywords in English

pressure sensor,two-dimensional correction,frequency domain

RIV year

2004

Released

23.05.2003

Publisher

Witpress

Location

Londýn

ISBN

1-85312-969-0

ISSN

0257-9731

Book

Computational Methods and Experimental Measurements XI

Journal

Journal of the Chinese Society of Mechanical Engineers

Volume

4

Edition number

1

Pages from–to

86–84

Pages count

9

BIBTEX


@inproceedings{BUT13512,
  author="Michal {Pohanka},
  title="Two-dimensional correction of data measured using a large pressure sensor",
  journal="Journal of the Chinese Society of Mechanical Engineers",
  booktitle="Computational Methods and Experimental Measurements XI",
  year="2003",
  volume="4",
  month="May",
  pages="86--84",
  publisher="Witpress",
  address="Londýn",
  isbn="1-85312-969-0",
  issn="0257-9731"
}