Original abstract

Fives Stein uses a cooling technology based on both side water spray for continuous annealing or galvanizing line. The aim of this project was to standardize or improve this cooling technology. Spray cooling visualizations were done first. Second, several spraying configuration were tested in order to study the influence of these parameters on the heat transfer coefficient. They were: spray distance, nozzle span, nozzle inclination angle, cooling header span, water pressure and nozzle type. Vertically moving testing bench was used for these tests. Results showed significant influence of some tested parameters on heat transfer coefficient. These results were sent to Fives Stein company and they will decided about cooling system improvements with respect to the costs.

Czech abstract

Společnost Fives Stein používá oboustranné chlazení tenkých plechů na žíhacích a zinkovacích linkách. Záměrem tohoto projektu bylo popsat či vylepšit stávající technologii chlazení. Nejprve byly provedeny teoretické vizualizace rozložení dopadající vody pro různé tlaky vody, pozice a typy trysek. Na základě těchto vizualizací byl navržen plán experimentů pro teplotní testy. Ty byly prováděny na speciálně navrženém testovacím zařízení pro simulaci chlazení vertikálně pohybujících se plechů. Vliv různých parametrů na součinitel přestupu tepla byl studován. Těmito parametry byly: rozteč trysek, úhel natočení trysek, vzdálenost trysek od chlazeného povrchu, rozteč chladicích kolektorů, tlak vody, různé typy trysek. Výsledky ukázaly značný vliv některých parametrů na součinitel přestupu tepla. Tyto výsledky byly předány společnosti Fives Stein, která na základě finanční analýzy rozhodne o úpravách stávajícího chladícího systému.

English abstract

Fives Stein uses a cooling technology based on both side water spray for continuous annealing or galvanizing line. The aim of this project was to standardize or improve this cooling technology. Spray cooling visualizations were done first. Second, several spraying configuration were tested in order to study the influence of these parameters on the heat transfer coefficient. They were: spray distance, nozzle span, nozzle inclination angle, cooling header span, water pressure and nozzle type. Vertically moving testing bench was used for these tests. Results showed significant influence of some tested parameters on heat transfer coefficient. These results were sent to Fives Stein company and they will decided about cooling system improvements with respect to the costs.

Keywords in Czech

galvanické zinkování, součinitel přestupu tepla, vodní chlazení, chlazení plechů

Keywords in English

Spray cooling, galvanizing line, heat transfer coefficient, strip cooling