Publication detail

Design of Semi-active Magnetorheological Valve with Non-magnetic Bypass

KUBÍK, M. MAZŮREK, I. ROUPEC, J. STRECKER, Z. MACHÁČEK, O.

Czech title

Návrh semi-aktivního magnetoreologického ventilu s nemagnetickým obtokem

English title

Design of Semi-active Magnetorheological Valve with Non-magnetic Bypass

Type

journal article - other

Language

en

Original abstract

The paper presents a methodology of design of a semi-active magnetorheological (MR) valve. The methodology was composed of the non-Newtonian fluid flow analysis and FEM analysis of a magnetic circuit. Based on the present methodology a MR valve was designed. The MR valve achieves damping force 1600 N at a velocity of 0.15 m/s. The time response was determined to 6 ms.

Czech abstract

Článek popisuje metodiku a návrh semi-aktivního magnetoreologického (MR) ventilu. Metodika byla sestavena z analýzy proudění nenewtonovské kapaliny a MKP analýzy magnetického obvodu. l. Transientní výpočet byl zásadní pro stanovení časové odezvy MR ventilu. Na základě předložené metodiky byl navržen semi-aktivní MR ventil. Navržený systém dosahuje tlumící síly 1600N při rychlosti 0,15 m/s. Časová odezva magnetického pole vypočtena na 6 ms.

English abstract

The paper presents a methodology of design of a semi-active magnetorheological (MR) valve. The methodology was composed of the non-Newtonian fluid flow analysis and FEM analysis of a magnetic circuit. Based on the present methodology a MR valve was designed. The MR valve achieves damping force 1600 N at a velocity of 0.15 m/s. The time response was determined to 6 ms.

Keywords in Czech

Magnetoreologický ventil, MR ventil, MR kapalina

Keywords in English

Magnetorheological valve, MR valve, MR fluid

RIV year

2015

Released

01.04.2015

ISSN

1805-3386

Volume

4

Number

1

Pages from–to

20–23

Pages count

4

BIBTEX


@article{BUT113904,
  author="Michal {Kubík} and Ivan {Mazůrek} and Jakub {Roupec} and Zbyněk {Strecker} and Ondřej {Macháček},
  title="Design of Semi-active Magnetorheological Valve with Non-magnetic Bypass",
  year="2015",
  volume="4",
  number="1",
  month="April",
  pages="20--23",
  issn="1805-3386"
}