Publication detail

TECHNIQUES OF MEASUREMENT OF SPRAY COOLING HOMOGENEITY

CHABIČOVSKÝ, M. RAUDENSKÝ, M.

Czech title

Techniky měření homogenity sprchového chlazení

English title

TECHNIQUES OF MEASUREMENT OF SPRAY COOLING HOMOGENEITY

Type

abstract

Language

en

Original abstract

The cooling homogeneity is one of the most important factors which must be considered when designing the cooling sections for hot rolling of thin sheets. The inhomogeneous cooling may origin an undesirable thermal distortion. The cooling homogeneity is mainly influenced by the water distribution of the cooling section. And so, one way how to measure the cooling homogeneity is to measure the impact pressure distribution of the cooling section. Another way is to measure the surface temperature distribution of a steel sample during the cooling process. There are two ways how to measure surface temperature and temperature field: contact and non-contact. Contact measurements are conducted with the help of thermocouples and noncontact measurements use an optical measurement, i.e. using an infrared-scanner. Each of these methods has their advantages and disadvantages. The comparison was demonstrated by the experimental cooling measurement of a stainless steel sheet done by full cone water nozzles.

Czech abstract

Homogenita chlazení je jedním z nejdůležitějších faktorů, které musí být brány do úvahy při navrhování chlazení pro válcování tenkých plechů. Nehomogenní chlazení může být původcem nežádoucí tepelné deformace. Homogenita chlazení je ovlivněn především rozložením dopadající vody. Jedním ze způsobů, jak měřit homogenitu chlazení je měření rozložení tlaku dopadající vody. Dalším způsobem je měření povrchové teploty ocelového vzorku v průběhu procesu chlazení. Existují dva způsoby, jak měřit povrchovou teplotu a teplotní pole: kontaktní a bezkontaktní. Kontaktní měření jsou prováděna s pomocí termočlánků a bezkontaktní měření pomocí optickýchmetod, jako je pomocí infračerveného-skener. Každá z těchto metod má své výhody a nevýhody. Porovnání těchto metod bylo provedeno při chlazení nerezového plechu chladící sekcí tvořenou kuželovými tryskami.

English abstract

The cooling homogeneity is one of the most important factors which must be considered when designing the cooling sections for hot rolling of thin sheets. The inhomogeneous cooling may origin an undesirable thermal distortion. The cooling homogeneity is mainly influenced by the water distribution of the cooling section. And so, one way how to measure the cooling homogeneity is to measure the impact pressure distribution of the cooling section. Another way is to measure the surface temperature distribution of a steel sample during the cooling process. There are two ways how to measure surface temperature and temperature field: contact and non-contact. Contact measurements are conducted with the help of thermocouples and noncontact measurements use an optical measurement, i.e. using an infrared-scanner. Each of these methods has their advantages and disadvantages. The comparison was demonstrated by the experimental cooling measurement of a stainless steel sheet done by full cone water nozzles.

Keywords in Czech

homogenita chlazení, kuželové trysky, součinitel přestupu tepla

Keywords in English

Cooling homogeneity, Full cone nozzles, Heat transfer coefficient

Released

13.11.2013

Publisher

Institute of Metals and Technology

Location

Ljubljana, Slovenija

ISBN

978-961-92518-6-7

Book

Program and book of abstracts, 21th Conference on Materials and Technology

Edition number

21

Pages from–to

58–58

Pages count

1