This paper presents the calibration of three universal ductile fracture criteria with the stress triaxiality and the normalized third invariant of deviatoric stress dependence. Xue-Wierzbicki, Bai-Wierzbicki and Extended Mohr-Coulomb criteria are calibrated using butterfly specimen and newly designed notched tube specimen for an austenitic stainless steel. Different stress states necessary for successful calibration are generated by suitable combination of tension/compression-shear or tension/compression-torsion loading of both specimens, respectively. Suitability of the specimens for ductile fracture criteria calibration is evaluated comparing the range of reached stress states, the homogeneity of stress in process zone and appropriateness for the computational simulation of tests. Possible combination of above mentioned results with tensile testing of standard and notched cylindrical specimens is discussed, too.
Czech abstract
Tento článek prezentuje kalibraci tří univerzálních kritérií tvárného porušování se závislostí na triaxialitě napětí a normalizovaném třetím invariantu deviátoru napětí. Xue-Wierzbicki, Bai-Wierzbicki a rozšířené Mohrovo-Coulombovo kritérium jsou kalibrovány s použitím vzorku ve tvaru motýla a nově navrženého vzorku, vrubované trubky, pro austenitickou ocel. Různé napěťové stavy, nezbytné pro úspěšnou kalibraci, jsou generovány pomocí vhodných kombinací zatěžování, tah/tlak-smyk nebo tah/tlak-krut, pro jeden a druhý vzorek. Vhodnost vzorků pro kalibraci kritérií tvárného porušování je ověřena porovnáním roztahu dosažených napěťových stavů, homogenity průběhu napětí a vhodnost pro počítačové simulace testů. Možná kombinace výše zmíněných výsledků spolu se zkoušením tahem standardních a vrubovaných válcových vzorků je také diskutována.
English abstract
This paper presents the calibration of three universal ductile fracture criteria with the stress triaxiality and the normalized third invariant of deviatoric stress dependence. Xue-Wierzbicki, Bai-Wierzbicki and Extended Mohr-Coulomb criteria are calibrated using butterfly specimen and newly designed notched tube specimen for an austenitic stainless steel. Different stress states necessary for successful calibration are generated by suitable combination of tension/compression-shear or tension/compression-torsion loading of both specimens, respectively. Suitability of the specimens for ductile fracture criteria calibration is evaluated comparing the range of reached stress states, the homogeneity of stress in process zone and appropriateness for the computational simulation of tests. Possible combination of above mentioned results with tensile testing of standard and notched cylindrical specimens is discussed, too.
Keywords in Czech
vzorek ve tvaru motýla, VT vzorek, identifikace parametrů, lomové přetvoření
Keywords in English
butterfly specimen, NT specimen, parameters identification, fracture strain
RIV year
2014
Released
14.02.2014
ISBN
9783037859346
ISSN
1013-9826
Book
Materials Structure & Micromechanics of Fracture VII
Volume
592-593
Pages from–to
258–261
Pages count
4
BIBTEX
@inproceedings{BUT102682,
author="Petr {Kubík} and František {Šebek} and Jindřich {Petruška} and Jiří {Hůlka} and Jan {Růžička} and Miroslav {Španiel} and Jan {Džugan} and Antonín {Prantl},
title="Calibration of Selected Ductile Fracture Criteria Using Two Types of Specimens",
booktitle="Materials Structure & Micromechanics of Fracture VII",
year="2014",
volume="592-593",
month="February",
pages="258--261",
isbn="9783037859346",
issn="1013-9826"
}