Originální abstrakt
This research report builds on previous two reports focused on description and evaluation of experiments of thermal and thermochemical disintegration of digested sludge. The effect on sludge dewatering was studied. Based on the laboratory tests the suitable conditions were chosen. A disintegration unit with the capacity of 10.8 t/d of a liquid sludge (refers to a wastewater treatment plant capacity of 10 000 population equivalents) was designed and the effect of disintegration of the back load of water line was assessed. Further, stress analysis and considerations concerning the vessel heating were elaborated. Finally, an economical evaluation of the process was carried out. In the evaluation, a payback period of approx. 15 y was determined, which emerges from the savings in sludge disposal.
Český abstrakt
Výzkumná zpráva navazuje na předchozí dvě zprávy, které prezentují výsledky laboratorních experimentů zaměřených na termickou a termochemickou desintegraci. Při těchto experimentech byl sledován vliv desintegrace na odvodnitelnost kalu, rovněž byly hledány vhodné provozní podmínky. Na základě provedených experimentů byla navržena desintegrační jednotka vč. periferií pro čistírnu o kapacitě 10 000 EO, byl proveden pevnostní výpočet a návrh ohřevu kalu. Dále bylo pro zvolené provozní podmínky vyhodnoceno zpětné zatížení vodní linky ČOV, neboť při desintegraci se výrazně zvyšuje obsah nerozpuštěných látek ve fugátu. Závěrem bylo provedeno ekonomické hodnocení zapojení desintegrace do technologie kalového hospodářství, které při využití kalu ke kompostování dopadlo poměrně nepříznivě. Z výpočtů vychází, že doba návratnosti je přibližně 15 let a to pouze v případě, že k ohřevu kalu při desintegraci bude použito jen odpadní teplo.
Anglický abstrakt
This research report builds on previous two reports focused on description and evaluation of experiments of thermal and thermochemical disintegration of digested sludge. The effect on sludge dewatering was studied. Based on the laboratory tests the suitable conditions were chosen. A disintegration unit with the capacity of 10.8 t/d of a liquid sludge (refers to a wastewater treatment plant capacity of 10 000 population equivalents) was designed and the effect of disintegration of the back load of water line was assessed. Further, stress analysis and considerations concerning the vessel heating were elaborated. Finally, an economical evaluation of the process was carried out. In the evaluation, a payback period of approx. 15 y was determined, which emerges from the savings in sludge disposal.
Klíčová slova česky
Čistírenský kal, vyhnilý kal, desintegrace, odvodnitelnost, odstřeďování, obsah sušiny, nitrifikace
Klíčová slova anglicky
Sewage sludge, digested sludge, disintegration, dewatering, centrifugation, total solids content, nitrification
Vydáno
14.11.2011
Nakladatel
VUT v Brně
Místo
Brno
Strany od–do
1–19
Počet stran
19
BIBTEX
@techreport{BUT88748,
author="Thomas {Elsässer} and Lucie {Houdková} and Filip {Brtna},
title="Thermal Disintegration of Sewage Sludge III",
year="2011",
month="November",
pages="1--19",
publisher="VUT v Brně",
address="Brno"
}