Zařízení pro experimentální modelování vlastností biomechanických soustav

BŘEZINA, T. HOUŠKA, P. BŘEZINA, L. ANDRŠ, O.

Český název

Zařízení pro experimentální modelování vlastností biomechanických soustav

Anglický název

Device for Experimental Modelling of Biomechanical Systems Properties

Typ

kapitola v knize

Jazyk

en

Originální abstrakt

The chapter presents one of control design possibilities for the cord implants testing device. The device was designed in such a way that its movements are as close as possible to the real physiological movements. General motion and effector action forces are simulated by parallel mechanism called Stewart platform (hexapod). Typically the hexapod structure has six linearly actuated legs, these are connected to the base plate and the top (mobile) plate by universal joints located at both of ends of the each leg. The six DOF top plate position and orientation depend on the length of each leg.

Český abstrakt

V kapitole je popsána jedna z možností návrhu řízení pro zařízení k testování páteřních implantátů. Zařízení bylo navrženo tak, aby jeho pohyby byly co nejbližší skutečným fyziologickým pohybům. Obecný pohyb a síly jsou simulovány pralelním mechanismem nazývqaným Stewartova platforma (hexapod). Struktura hexapodu má typicky šest lineárně poháněných noh, které jsou připojeny k základní desce a horní (pohyblivé desce) uverzálními vazbami připojenými na koncích každé z noh. Poloha a orientace horní desky se šesti stupni volnosti závisí na délce každé z noh.

Anglický abstrakt

The chapter presents one of control design possibilities for the cord implants testing device. The device was designed in such a way that its movements are as close as possible to the real physiological movements. General motion and effector action forces are simulated by parallel mechanism called Stewart platform (hexapod). Typically the hexapod structure has six linearly actuated legs, these are connected to the base plate and the top (mobile) plate by universal joints located at both of ends of the each leg. The six DOF top plate position and orientation depend on the length of each leg.

Klíčová slova česky

biomechanika;mechatronika

Klíčová slova anglicky

biomechanics; mechatronics

Rok RIV

2007

Vydáno

15.12.2007

Nakladatel

VUT v Brně

Místo

Brno

ISBN

978-80-214-3559-9

Kniha

Simulation Modelling of Mechatronic Systems III

Číslo edice

1

Strany od–do

229–240

Počet stran

12

BIBTEX


@inbook{BUT55559,
  author="Tomáš {Březina} and Pavel {Houška} and Lukáš {Březina} and Ondřej {Andrš},
  title="Device for Experimental Modelling of Biomechanical Systems Properties",
  booktitle="Simulation Modelling of Mechatronic Systems III",
  year="2007",
  month="December",
  pages="229--240",
  publisher="VUT v Brně",
  address="Brno",
  isbn="978-80-214-3559-9"
}