Capture efficiency measurement of pollutants over a workbench with the reinforced slot exhaust system
PECH, O. PAVELEK, M.
Český název
Capture efficiency measurement of pollutants over a workbench with the reinforced slot exhaust system
Anglický název
Capture efficiency measurement of pollutants over a workbench with the reinforced slot exhaust system
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
en
Originální abstrakt
The paper deals with the measurement of the capture efficiency of pollutants by the slot reinforced exhaust system situated in two positions over the workbench. The slot reinforced exhaust system, which is known as REEXS, is the traditional slot exhaust hood equipped with an air supply inlet that intensifies exhausting along the axis of the exhaust hood. It can operate in traditional or reinforced exhaust modes. Measurements were made for the same air velocity in the suction slot and with the different momentum flux ratio of supplied and exhausted air flow. The tracer gas method was used for the capture efficiency measurement of the system. As the tracer gas the carbon dioxide was chosen. The knowledge of the shape and range of the effective exhaust area for various configurations in front of the exhaust hood is important for the exhaust hood setting according to a source of pollutants.
Český abstrakt
The paper deals with the measurement of the capture efficiency of pollutants by the slot reinforced exhaust system situated in two positions over the workbench. The slot reinforced exhaust system, which is known as REEXS, is the traditional slot exhaust hood equipped with an air supply inlet that intensifies exhausting along the axis of the exhaust hood. It can operate in traditional or reinforced exhaust modes. Measurements were made for the same air velocity in the suction slot and with the different momentum flux ratio of supplied and exhausted air flow. The tracer gas method was used for the capture efficiency measurement of the system. As the tracer gas the carbon dioxide was chosen. The knowledge of the shape and range of the effective exhaust area for various configurations in front of the exhaust hood is important for the exhaust hood setting according to a source of pollutants.
Anglický abstrakt
The paper deals with the measurement of the capture efficiency of pollutants by the slot reinforced exhaust system situated in two positions over the workbench. The slot reinforced exhaust system, which is known as REEXS, is the traditional slot exhaust hood equipped with an air supply inlet that intensifies exhausting along the axis of the exhaust hood. It can operate in traditional or reinforced exhaust modes. Measurements were made for the same air velocity in the suction slot and with the different momentum flux ratio of supplied and exhausted air flow. The tracer gas method was used for the capture efficiency measurement of the system. As the tracer gas the carbon dioxide was chosen. The knowledge of the shape and range of the effective exhaust area for various configurations in front of the exhaust hood is important for the exhaust hood setting according to a source of pollutants.
Klíčová slova česky
Industrial ventilation, REEXS, exhausting, slot exhaust hood, tracer gas method, capture efficiency.
Klíčová slova anglicky
Industrial ventilation, REEXS, exhausting, slot exhaust hood, tracer gas method, capture efficiency.
Rok RIV
2013
Vydáno
09.04.2013
Nakladatel
EDP Sciences
Místo
Francie
ISBN
978-80-7372-912-7
ISSN
2100-014X
Kniha
Proceedings of the International conference Experimental Fluid Mechanics 2012
Ročník
45
Číslo
1
Strany od–do
1–4
Počet stran
4
BIBTEX
@inproceedings{BUT99183,
author="Ondřej {Pech} and Milan {Pavelek},
title="Capture efficiency measurement of pollutants over a workbench with the reinforced slot exhaust system",
booktitle="Proceedings of the International conference Experimental Fluid Mechanics 2012",
year="2013",
volume="45",
number="1",
month="April",
pages="1--4",
publisher="EDP Sciences",
address="Francie",
isbn="978-80-7372-912-7",
issn="2100-014X"
}