Deformačně napěťová analýza kyčelního kloubu po aplikaci totální endoprotézy se zahrnutím otěru

EBRINGEROVÁ, V. MARCIÁN, P. VALÁŠEK, J. FLORIAN, Z.

Český název

Deformačně napěťová analýza kyčelního kloubu po aplikaci totální endoprotézy se zahrnutím otěru

Anglický název

Stress-Strain Analysis of Hip Joint after Application of Total Hip Arthroplasty with Consideration of Wear

Typ

článek v časopise - ostatní, Jost

Jazyk

en

Originální abstrakt

The presented work deals with the creation of computational model of total hip arthroplasty and the subsequent performance stress-strain analysis. The models of geometry of the pelvis and femur were created on base of CT data. In this model were fitted both of components, i.e. femoral stem and acetabular liner. On this system was subsequently modeled the real load conditions. Just real loading of the prosthesis leads to wear and it has great influence on the deterioration of bone tissue. These properties were simulated under the acetabular component. The behavior of the whole system is assessed on base of stress-strain analysis. From comparison the obtained results with clinical study it is evident that the places that are dangerous in terms of establishment wear particles are identical. This whole issue is very topical today.

Český abstrakt

Předložená práce se zabývá tvorbou výpočtového modelu totální náhrady kyčelního kloubu a následné deformačně-napěťové analýzy. Tyto modely geometrie pánve a stehenní kosti byly vytvořeny na základě dat z CT. Výpočtový model obsahuje dřík totální endoprotézy tak i jamku. Na této soustavě byly simulovány skutečné podmínky zatížení. Chování celého soustavy je hodnocena na deformačně-napěťové analýzy.

Anglický abstrakt

The presented work deals with the creation of computational model of total hip arthroplasty and the subsequent performance stress-strain analysis. The models of geometry of the pelvis and femur were created on base of CT data. In this model were fitted both of components, i.e. femoral stem and acetabular liner. On this system was subsequently modeled the real load conditions. Just real loading of the prosthesis leads to wear and it has great influence on the deterioration of bone tissue. These properties were simulated under the acetabular component. The behavior of the whole system is assessed on base of stress-strain analysis. From comparison the obtained results with clinical study it is evident that the places that are dangerous in terms of establishment wear particles are identical. This whole issue is very topical today.

Klíčová slova česky

Totální endoprotéza kyčelního kloubu; otěr

Klíčová slova anglicky

Total hip endoprosthesis; Wear; Ultra High Molecular Weight Polyetylene

Rok RIV

2013

Vydáno

03.01.2013

Nakladatel

Trans Tech Publication

Místo

Switzerland

ISSN

1660-9336

Ročník

245

Číslo

1

Strany od–do

80–84

Počet stran

5

BIBTEX


@article{BUT94879,
  author="Veronika {Ebringerová} and Petr {Marcián} and Jiří {Valášek} and Zdeněk {Florian},
  title="Stress-Strain Analysis of Hip Joint after Application of Total Hip Arthroplasty with Consideration of Wear",
  year="2013",
  volume="245",
  number="1",
  month="January",
  pages="80--84",
  publisher="Trans Tech Publication",
  address="Switzerland",
  issn="1660-9336"
}