Detail publikace

Studie výmeníku tepla z dutých polymerních vláken

ASTROUSKI, I. RAUDENSKÝ, M.

Český název

Studie výmeníku tepla z dutých polymerních vláken

Anglický název

THE STUDY OF POLYMERIC HOLLOW FIBER HEAT EXCHANGERS

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

The polymeric hollow fiber heat exchanger (PHFHE) is a modern type of apparatus which uses polymeric fibers, with a small diameter around 1 mm, for separation of the heat transfer mediums. The main goal of this work is to study different factors which affect heat transfer in polymeric hollow fibers (diameters, length and material of fibers, liquids temperatures and velocities) and to obtain conclusions concerning hollow fiber application. The values of external, internal as well as overall heat transfer coefficient, heat transfer rate, number of transfer units (NTUs), efficiency and pressure drops were obtained for both water-water and water-air applications. The special performed Delphi-based software was prepared to accelerate the computation process.

Český abstrakt

Polymerní výměník tepla (PHFHE) z dutých vláken je moderní typ přístroje, které používá polymerný vlákna, s malým průměrem kolem 1 mm, pro oddělení médií přenosu tepla. Hlavním cílem této práce je studovat různé faktory, které ovlivňují přenos tepla v polymerních dutých vláknech (průměry, délky a materiál vláken, kapaliny, teploty a rychlosti) a získat závěry týkající se aplikace dutých vláken. Hodnoty vnější, vnitřní i celkové součinitele prostupu tepla a tepelný výkon, počet převodních jednotek (NTUs), účinnost a poklesu tlaku byly získané pro proudení voda-voda a voda-vzduch. V Delphi byl napsan program k urychlení výpočetního procesu.

Anglický abstrakt

The polymeric hollow fiber heat exchanger (PHFHE) is a modern type of apparatus which uses polymeric fibers, with a small diameter around 1 mm, for separation of the heat transfer mediums. The main goal of this work is to study different factors which affect heat transfer in polymeric hollow fibers (diameters, length and material of fibers, liquids temperatures and velocities) and to obtain conclusions concerning hollow fiber application. The values of external, internal as well as overall heat transfer coefficient, heat transfer rate, number of transfer units (NTUs), efficiency and pressure drops were obtained for both water-water and water-air applications. The special performed Delphi-based software was prepared to accelerate the computation process.

Klíčová slova česky

Polymerní dutá vlákna, výměník tepla, přenos tepla.

Klíčová slova anglicky

Polymeric hollow fibers, heat exchanger, heat transfer.

Rok RIV

2012

Vydáno

14.05.2012

Místo

Svratka

ISBN

978-80-86246-40-6

Kniha

Engineering Mechanics 2012

Číslo edice

1

Strany od–do

47–57

Počet stran

11

BIBTEX


@inproceedings{BUT92128,
  author="Ilja {Astrouski} and Miroslav {Raudenský},
  title="THE STUDY OF POLYMERIC HOLLOW FIBER HEAT EXCHANGERS",
  booktitle="Engineering Mechanics 2012",
  year="2012",
  month="May",
  pages="47--57",
  address="Svratka",
  isbn="978-80-86246-40-6"
}