Deformačně napěťová analýza dolní končetiny s aplikovaným fixátorem

MRÁZEK, M. FLORIAN, Z. VESELÝ, R. BORÁK, L.

Český název

Deformačně napěťová analýza dolní končetiny s aplikovaným fixátorem

Anglický název

Strain-stress analysis of lower limb with applied fixator

Typ

článek v časopise - ostatní, Jost

Jazyk

en

Originální abstrakt

Treatment of complicated fractures is much more difficult than the treatment of simple fractures. Bone tissue but also soft tissue injuries happen in most cases. That is why plaster bandage cannot be used for fracture fixation. Fixators are used to fixate the fractured bones in this case. Fixators are furthermore used in the treatment of limb imperfections where damaged area must be overbridged. The fixation has principal influence on quality of bone concretion. Fixator must be able to transport the load arising during walking. Stiffness of a system fixator: bone should be the same as stiffness of single bone. The second criteria of fixator functionality is no overloading of bone tissue during the treatment. Two types of the most often applied fixators were studied in terms of suggestion from Trauma Hospital of Brno. Both fixators belong to the category of axial fixators. This paper is concerned with the study of stiffness of two systems fixator: bone via strain-stress analysis and their comparison with physiological state of bone.

Český abstrakt

K léčbě komplikovaných zlomenin se používají fixátory, přičemž fixace má zasádní vliv na kvalitu léčby. Fixátor musí být schopen přenášet zatížení vznikající během chůze. Tuhost systému fixátor-kost by měla být stejná jako u zdravé kosti. Dalším kritériem funkčnosti fixátoru je nepřetěžování kostní tkáně během léčby. Na návrh Úrazové nemocnice Brno jsou zde studovány dva typy nejčastěji používaných fixátorů patřících do kategorie axiálních fixátorů. Práze se zabývá studiem tuhosti systémů fixátor-kost pomocí deformačně naěťové analýzy a jejich srovnáním s fyziologickým stavem tibie.

Anglický abstrakt

Treatment of complicated fractures is much more difficult than the treatment of simple fractures. Bone tissue but also soft tissue injuries happen in most cases. That is why plaster bandage cannot be used for fracture fixation. Fixators are used to fixate the fractured bones in this case. Fixators are furthermore used in the treatment of limb imperfections where damaged area must be overbridged. The fixation has principal influence on quality of bone concretion. Fixator must be able to transport the load arising during walking. Stiffness of a system fixator: bone should be the same as stiffness of single bone. The second criteria of fixator functionality is no overloading of bone tissue during the treatment. Two types of the most often applied fixators were studied in terms of suggestion from Trauma Hospital of Brno. Both fixators belong to the category of axial fixators. This paper is concerned with the study of stiffness of two systems fixator: bone via strain-stress analysis and their comparison with physiological state of bone.

Klíčová slova česky

tibie, fixátor, metoda konečných prvků, deformačně napěťová analýza

Klíčová slova anglicky

tibia, fixator, finite element method, stress-strain analysis

Rok RIV

2010

Vydáno

30.07.2010

Nakladatel

University of West Bohemia

Místo

Plzeň

ISSN

1802-680X

Časopis

Applied and Computational Mechanics

Ročník

4

Číslo

1

Strany od–do

67–78

Počet stran

12

BIBTEX


@article{BUT50287,
  author="Michal {Mrázek} and Zdeněk {Florian} and Radek {Veselý} and Libor {Borák},
  title="Strain-stress analysis of lower limb with applied fixator",
  journal="Applied and Computational Mechanics",
  year="2010",
  volume="4",
  number="1",
  month="July",
  pages="67--78",
  publisher="University of West Bohemia",
  address="Plzeň",
  issn="1802-680X"
}