Detail publikace

Porovnání využítí kogenerační a trigenerační technologie v budovách komunální sféry

POSPÍŠIL, J. FIEDLER, J. SKÁLA, Z.

Český název

Porovnání využítí kogenerační a trigenerační technologie v budovách komunální sféry

Anglický název

Comparison of Cogeneration and Trigeneration Technology for Energy Supply of Tertiary Buildings

Typ

článek v časopise - ostatní, Jost

Jazyk

en

Originální abstrakt

This paper introduces possible utilizing of poly-generation for complex energy supply of tertiary buildings. Poly-generation represents more effective conversion of primary energy sources in comparison with separate production of different kinds of energies. A cogeneration unit producing electricity and heat is considered as the most common poly-generation system and compared with operation of a power plant and a central heating system. Another considered poly-generation system is a trigeneration technology. This system consists from a cogeneration unit conected with a convenient absorption system for production of cool water. The mixture of water and LiBr is considered as appropriate working medium operating in the absorption cycle. This paper focuses on comparison of utilizing of cogeneration and trigeneration technology in tertiary buildings. Different parameters of the absorption system are tested and evaluated. Design of the absorption cycle is present with detail information about temperatures and pressures in all important points of the cycle. Influence of the absorption cycle components efficiency on the total cycle efficiency is calculated. Diagrams of annual required heat energy are drawn for a particular building utilizing i) cogeneration and ii) trigeneration technology.

Český abstrakt

This paper introduces possible utilizing of poly-generation for complex energy supply of tertiary buildings. Poly-generation represents more effective conversion of primary energy sources in comparison with separate production of different kinds of energies. A cogeneration unit producing electricity and heat is considered as the most common poly-generation system and compared with operation of a power plant and a central heating system. Another considered poly-generation system is a trigeneration technology. This system consists from a cogeneration unit conected with a convenient absorption system for production of cool water. The mixture of water and LiBr is considered as appropriate working medium operating in the absorption cycle. This paper focuses on comparison of utilizing of cogeneration and trigeneration technology in tertiary buildings. Different parameters of the absorption system are tested and evaluated. Design of the absorption cycle is present with detail information about temperatures and pressures in all important points of the cycle. Influence of the absorption cycle components efficiency on the total cycle efficiency is calculated. Diagrams of annual required heat energy are drawn for a particular building utilizing i) cogeneration and ii) trigeneration technology.

Anglický abstrakt

This paper introduces possible utilizing of poly-generation for complex energy supply of tertiary buildings. Poly-generation represents more effective conversion of primary energy sources in comparison with separate production of different kinds of energies. A cogeneration unit producing electricity and heat is considered as the most common poly-generation system and compared with operation of a power plant and a central heating system. Another considered poly-generation system is a trigeneration technology. This system consists from a cogeneration unit conected with a convenient absorption system for production of cool water. The mixture of water and LiBr is considered as appropriate working medium operating in the absorption cycle. This paper focuses on comparison of utilizing of cogeneration and trigeneration technology in tertiary buildings. Different parameters of the absorption system are tested and evaluated. Design of the absorption cycle is present with detail information about temperatures and pressures in all important points of the cycle. Influence of the absorption cycle components efficiency on the total cycle efficiency is calculated. Diagrams of annual required heat energy are drawn for a particular building utilizing i) cogeneration and ii) trigeneration technology.

Klíčová slova anglicky

cogeneration, trigeneration, absorption cycle, tertiary buildings

Rok RIV

2006

Vydáno

01.03.2006

Nakladatel

WSEAS

ISSN

1790-5044

Časopis

WSEAS Transaction on Heat and Mass Transfer

Ročník

1

Číslo

3

Strany od–do

262–267

Počet stran

6

BIBTEX


@article{BUT43401,
  author="Jiří {Pospíšil} and Jan {Fiedler} and Zdeněk {Skála},
  title="Comparison of Cogeneration and Trigeneration Technology for Energy Supply of Tertiary Buildings",
  journal="WSEAS Transaction on Heat and Mass Transfer",
  year="2006",
  volume="1",
  number="3",
  month="March",
  pages="262--267",
  publisher="WSEAS",
  issn="1790-5044"
}