Pevná fixace oleokranonu. Srovnání dvou operačních technik.
PÍŠKA, M.
Český název
Pevná fixace oleokranonu. Srovnání dvou operačních technik.
Anglický název
Rigid olecranon fixation: A comparison of two techniques
Typ
článek v časopise - ostatní, Jost
Jazyk
en
Originální abstrakt
A new fixation with threaded Medin K wires has been compared with standard AO technique for a two twist techniques. Thawed fresh frozen human elbow joints were used for this study. The gap distraction increased when a moment was applied and almost returned to its previous state when the moment was removed due to visco-elastic behaviour of the ligament. Early gap opening seems to be a featur of the TBW when loaded. The new technique of two partially threaded K wires may compete with the fixation of the two twist TBW under these clinical conditions.
Český abstrakt
Nový způsob fixace pomocí dvou K-drátů Medin byl srovnáván se standardní cirklážní AO technikou. Ke studiu byly použity čerstvě rozmražené lidské loketní klouby. Při zatěžování TBW spoje rostoucím ohybovým momentem bylo pozorováno rozevírání lomové plochy v důsledku visko-elastického chování vaziva. Technika TBW se vyznačovala zrychleným rozevíráním lomových ploch. Nová technika pomocí dvou zkřížených K-drátů Medin tento problém účinně eliminovala a odstranila řadu dalších problémů tahové cirkláže.
Anglický abstrakt
A new fixation with threaded Medin K wires has been compared with standard AO technique for a two twist techniques. Thawed fresh frozen human elbow joints were used for this study. The gap distraction increased when a moment was applied and almost returned to its previous state when the moment was removed due to visco-elastic behaviour of the ligament. Early gap opening seems to be a featur of the TBW when loaded. The new technique of two partially threaded K wires may compete with the fixation of the two twist TBW under these clinical conditions.
Klíčová slova česky
oleocranon, fixace, K-drát
Klíčová slova anglicky
oleocranon, fixation, K-wire
Rok RIV
2004
Vydáno
01.11.1998
Nakladatel
BORS Oxford
Místo
Oxford
ISSN
0310-620X
Časopis
Journal of Bone and Joint Surgery (Br)
Ročník
1998
Číslo
80(B)
Strany od–do
258–258
Počet stran
1
BIBTEX
@article{BUT41181,
author="Miroslav {Píška},
title="Rigid olecranon fixation: A comparison of two techniques",
journal="Journal of Bone and Joint Surgery (Br)",
year="1998",
volume="1998",
number="80(B)",
month="November",
pages="258--258",
publisher="BORS Oxford",
address="Oxford",
issn="0310-620X"
}