Detail publikace
Study of process parameters of the atomizer-based spray gun for the application of a temporary matte coating for 3D scanning purposes
FRANKE, J. KOUTECKÝ, T. MALÝ, M. KALINA, M. KOUTNÝ, D.
Anglický název
Study of process parameters of the atomizer-based spray gun for the application of a temporary matte coating for 3D scanning purposes
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
en
Originální abstrakt
The aim of this paper is to find the most suitable process parameters of the spray gun for the deposition of matte coating for 3D optical scanning purposes. The membrane atomizer-based spray gun is used as a coating device. A suspension of TiO2 and ethanol is used as a coating material. In this study, the formed spray is analyzed using Phase Doppler Anemometry and the results are compared to the deposited coatings. Applied coatings are further examined using a profilometer and 3D scanner to analyze their thickness and the effect they have on the 3D surface reconstruction. The results of this work show that two spray layers are sufficient to evenly apply a coating with good properties for 3D optical scanning purposes. The coating thickness is below 1 μm, reference area is entirely scanned, and the scanned point cloud has a standard deviation from the reference plane below 1.1 μm.
Anglický abstrakt
The aim of this paper is to find the most suitable process parameters of the spray gun for the deposition of matte coating for 3D optical scanning purposes. The membrane atomizer-based spray gun is used as a coating device. A suspension of TiO2 and ethanol is used as a coating material. In this study, the formed spray is analyzed using Phase Doppler Anemometry and the results are compared to the deposited coatings. Applied coatings are further examined using a profilometer and 3D scanner to analyze their thickness and the effect they have on the 3D surface reconstruction. The results of this work show that two spray layers are sufficient to evenly apply a coating with good properties for 3D optical scanning purposes. The coating thickness is below 1 μm, reference area is entirely scanned, and the scanned point cloud has a standard deviation from the reference plane below 1.1 μm.
Klíčová slova anglicky
3D scanning; Matte coating; Atomization; Titanium dioxide; Phase Doppler anemometry
Vydáno
15.04.2022
Nakladatel
Elsevier Ltd
Místo
Švýcarská konfederace
ISSN
0254-0584
Ročník
282
Číslo
15 April 2022
Strany od–do
1–16
Počet stran
16
BIBTEX
@article{BUT178013,
author="Jakub {Franke} and Tomáš {Koutecký} and Milan {Malý} and Michal {Kalina} and Daniel {Koutný},
title="Study of process parameters of the atomizer-based spray gun for the application of a temporary matte coating for 3D scanning purposes",
year="2022",
volume="282",
number="15 April 2022",
month="April",
pages="1--16",
publisher="Elsevier Ltd",
address="Švýcarská konfederace",
issn="0254-0584"
}