Detail publikace
Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification
KUBÍK, M. ŠEBESTA, K. STRECKER, Z. JENIŠ, F. GOLDASZ, J. MAZŮREK, I.
Anglický název
Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
en
Originální abstrakt
The transient behaviour of magnetorheological (MR) actuators affects their performance in progressive semiactive control suspension systems. The two sources of the time delay between the control signal and damping force are (i) dynamics of MR damper hardware and (ii) the MR fluid dynamics. The significant part of the MR fluid response time is the so-called hydrodynamic response time which is connected with the transient flow. Due to the above, the main aim of this paper is to experimentally determine the hydrodynamic response time of MR fluid and present systematic means for characterizing it via computational fluid dynamics (CFD) or analytical tools. The unique measurement method using an in-house patented slit flow rheometer is presented. The essence of the method relies on determining the pressure drop variation with the time spent by the fluid in the MR gap. The experimental determined hydrodynamic response time of MR fluid ranges from 0.4 ms to 1 ms for a selected gap size and a range of magnetic field stimuli. The results show that the higher the magnetic field, the lower the hydrodynamic response time is. Both CFD and analytical models exhibit similar trends as the experimental data. Moreover, the impact of temperature and gap size was determined. Here, the higher the gap size and temperature of MR fluid, the longer the response time is.
Anglický abstrakt
The transient behaviour of magnetorheological (MR) actuators affects their performance in progressive semiactive control suspension systems. The two sources of the time delay between the control signal and damping force are (i) dynamics of MR damper hardware and (ii) the MR fluid dynamics. The significant part of the MR fluid response time is the so-called hydrodynamic response time which is connected with the transient flow. Due to the above, the main aim of this paper is to experimentally determine the hydrodynamic response time of MR fluid and present systematic means for characterizing it via computational fluid dynamics (CFD) or analytical tools. The unique measurement method using an in-house patented slit flow rheometer is presented. The essence of the method relies on determining the pressure drop variation with the time spent by the fluid in the MR gap. The experimental determined hydrodynamic response time of MR fluid ranges from 0.4 ms to 1 ms for a selected gap size and a range of magnetic field stimuli. The results show that the higher the magnetic field, the lower the hydrodynamic response time is. Both CFD and analytical models exhibit similar trends as the experimental data. Moreover, the impact of temperature and gap size was determined. Here, the higher the gap size and temperature of MR fluid, the longer the response time is.
Klíčová slova anglicky
transient rheology; unsteady flow; hydrodynamic response time; response time; time constant; MR fluid, MR damper; magnetorheological fluid
Vydáno
11.11.2021
ISSN
0964-1726
Ročník
30
Číslo
12
Strany od–do
1–13
Počet stran
13
BIBTEX
@article{BUT173006,
author="Michal {Kubík} and Karel {Šebesta} and Zbyněk {Strecker} and Filip {Jeniš} and Janusz {Goldasz} and Ivan {Mazůrek} and Goldasz {Janusz},
title="Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification",
year="2021",
volume="30",
number="12",
month="November",
pages="1--13",
issn="0964-1726"
}