Detail publikace

THE EFFECT OF REMAINING WATER LAYER ON FINAL TEMPERATURE OF STEEL PLATE DURING HOT ROLLING

RESL, O. POHANKA, M.

Anglický název

THE EFFECT OF REMAINING WATER LAYER ON FINAL TEMPERATURE OF STEEL PLATE DURING HOT ROLLING

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

Steel products like hot rolled steel plates or strips are widely used in industry or in other fields of human activity. Prediction and control of cooling during hot rolling are necessary to obtain the desired mechanical properties of the hot rolled steel. Spray and laminar cooling are common ways of cooling of the hot rolled strip on a run-out table in many steel industries today. Disadvantage of water cooling is remaining water on the surface of the steel strip that is accumulated and forms a water layer on upper surface. Due to the presence of the water layer, jets do not impact on the steel surface directly and the cooling intensity is changed. In this article, simulations of top and bottom cooling of the steel strip on the run-out table during hot rolling are performed using experimentally obtained boundary conditions. The experiment for obtaining boundary conditions is also described. Simulation with remaining water on the surface and simulation where the effect of the water layer was neglected are compared and the influence of the remaining water on the final temperature of the steel strip, which is an important parameter to control the quality of the final product, is investigated.

Anglický abstrakt

Steel products like hot rolled steel plates or strips are widely used in industry or in other fields of human activity. Prediction and control of cooling during hot rolling are necessary to obtain the desired mechanical properties of the hot rolled steel. Spray and laminar cooling are common ways of cooling of the hot rolled strip on a run-out table in many steel industries today. Disadvantage of water cooling is remaining water on the surface of the steel strip that is accumulated and forms a water layer on upper surface. Due to the presence of the water layer, jets do not impact on the steel surface directly and the cooling intensity is changed. In this article, simulations of top and bottom cooling of the steel strip on the run-out table during hot rolling are performed using experimentally obtained boundary conditions. The experiment for obtaining boundary conditions is also described. Simulation with remaining water on the surface and simulation where the effect of the water layer was neglected are compared and the influence of the remaining water on the final temperature of the steel strip, which is an important parameter to control the quality of the final product, is investigated.

Klíčová slova anglicky

Steel, temperature, water, cooling, heat transfer coefficient

Vydáno

22.05.2019

Nakladatel

Tanger, Ostrava

Místo

Ostrava

ISBN

978-80-87294-92-5

Kniha

METAL 2019 Conference Proceedings

Strany od–do

355–360

Počet stran

6

BIBTEX


@inproceedings{BUT157699,
  author="Ondřej {Resl} and Michal {Pohanka},
  title="THE EFFECT OF REMAINING WATER LAYER ON FINAL TEMPERATURE OF STEEL PLATE DURING HOT ROLLING",
  booktitle="METAL 2019 Conference Proceedings",
  year="2019",
  month="May",
  pages="355--360",
  publisher="Tanger, Ostrava",
  address="Ostrava",
  isbn="978-80-87294-92-5"
}