Medical grade 3D printing offers the possibility to manufacture patient-specific implants to treat cranial defects. The performance of the implant assembly depends on many factors, such as material, thickness, size and manufacturing accuracy. A significant factor in the stability and success of the assembly is the fixation method. Cranial implants are usually fixed to the skull by means of mini-plates. Biomechanical assessment of fixing the implant to the skull might be helpful not only for mini-plate design but might be beneficial also for the surgeons. In this study, four different mini-plate designs were analyzed and compared based on the stress-strain analysis of one cranial implant fixed at three locations by mini-plates. Computational simulations were done using Finite Element Method.
Český abstrakt
3D tisk nabízí možnost výroby implantátů například k léčbě defektů lebky tzv. individualistickým přístupem. Mechanické vlastnosti implantátu závisí na mnoha faktorech, jako je materiál, tloušťka, velikost a přesnost výroby. Dalším významným faktorem je způsob uchycení implantátu v lebce pomocí fixátorů. Kraniální implantáty jsou obvykle fixovány na lebku pomocí mini-destiček. Biomechanické posouzení fixace implantátu na lebku by mohlo být užitečné nejen pro konstrukci mini-destiček, ale mohlo by být prospěšné i pro chirurgy. V této studii byly analyzovány čtyři různé fixační destičky a porovnány na základě analýzy napětí a deformace. Výpočtové simulace byly provedeny metodou konečných prvků.
Anglický abstrakt
Medical grade 3D printing offers the possibility to manufacture patient-specific implants to treat cranial defects. The performance of the implant assembly depends on many factors, such as material, thickness, size and manufacturing accuracy. A significant factor in the stability and success of the assembly is the fixation method. Cranial implants are usually fixed to the skull by means of mini-plates. Biomechanical assessment of fixing the implant to the skull might be helpful not only for mini-plate design but might be beneficial also for the surgeons. In this study, four different mini-plate designs were analyzed and compared based on the stress-strain analysis of one cranial implant fixed at three locations by mini-plates. Computational simulations were done using Finite Element Method.
Klíčová slova česky
Kraniální implantát; Fixátory; MKP; Polymethylmethakrylát; Deformačně-napěťová analýza
Klíčová slova anglicky
Cranial implants; Fixation mini-plates; FEA; Polymethyl Methacrylate; Stress-strain analysis
Vydáno
13.06.2017
Nakladatel
Springer
ISSN
1680-0737
Kniha
EMBEC’17 & NBC’17
Ročník
1
Číslo
65
Strany od–do
747–750
Počet stran
4
BIBTEX
@inproceedings{BUT137072,
author="Jakub {Chamrad} and Petr {Marcián} and Nathaniel {Narra} and Libor {Borák},
title="Evaluating Different Shapes of Cranial Fixation Mini-plates Using Finite Element Method",
booktitle="EMBEC’17 & NBC’17",
year="2017",
volume="1",
number="65",
month="June",
pages="747--750",
publisher="Springer",
issn="1680-0737"
}