Design and testing of magnetorheological valve with fast force response time and great dynamic force range

KUBÍK, M. MACHÁČEK, O. ROUPEC, J. STRECKER, Z. MAZŮREK, I.

Anglický název

Design and testing of magnetorheological valve with fast force response time and great dynamic force range

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

en

Originální abstrakt

The paper deals with design, simulation and experimental testing of a magnetorheological (MR) valve with short response time. The short response time is achieved by a suitable design of an active zone in combination with use of a ferrite material for magnetic circuit. The magneto-static model and the simplified hydraulic model of the MR valve are examined and experimentally verified. The development the MR valve achieves an average response time 4.1 ms and the maximum dynamic force range of eight.

Anglický abstrakt

The paper deals with design, simulation and experimental testing of a magnetorheological (MR) valve with short response time. The short response time is achieved by a suitable design of an active zone in combination with use of a ferrite material for magnetic circuit. The magneto-static model and the simplified hydraulic model of the MR valve are examined and experimentally verified. The development the MR valve achieves an average response time 4.1 ms and the maximum dynamic force range of eight.

Klíčová slova anglicky

MR fluid, magnetorheological fluid, MR damper, magnetorheological damper

Vydáno

07.03.2017

ISSN

0964-1726

Ročník

26

Číslo

4

Strany od–do

1–10

Počet stran

10