Detail publikace

Použití metody akustické emise pro diagnostiku poškození pneumatických válců

MAZAL, P. VLAŠIC, F. MAHMOUD, H. JANA, M.

Český název

Použití metody akustické emise pro diagnostiku poškození pneumatických válců

Anglický název

The Use of Acoustic Emission Method for Diagnosis of Damage of Pneumatic Cylinders

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

The paper presents the latest results obtained in the course of the project Technology Agency of the Czech Republic, which aims to create a new diagnostic system for checking the function of pneumatic cylinders using acoustic emission. There are compared the records of the AE signal from the undamaged pneumatic cylinders and similar entries from cylinders containing artificial defects. Records of signals are monitored by modern analysers DAKEL IPL with full sampling of the signal. Based on the analysis of large data sets are selected suitable AE signal parameters, which can be used for more accurately diagnostics of condition of tested devices which could be used for constructing of analyser for testing of pneumatic devices.

Český abstrakt

Článek prezentuje nejnovější výsledky získané v průběhu řešení projektu Technologické agentury České republiky, jehož cílem je vytvořit nový diagnostický systém pro kontrolu funkce pneumatických válců pomocí akustické emise. Záznamy AE signálu z nepoškozených pneumatických válců a podobných položek z válců obsahujících umělé defekty jsou porovnány. Záznamy signálu jsou sledovány moderní mianalyzátory DAKEL IPL s plným vzorkováním signálu. Na základě analýzy velkých datových sad jsou vybrány vhodné parametry signálu AE, které lze použít pro přesnější diagnostiku stavu testovaných zařízení, které by mohly být použity pro konstrukci analyzátoru pro testování pneumatické zařízení.

Anglický abstrakt

The paper presents the latest results obtained in the course of the project Technology Agency of the Czech Republic, which aims to create a new diagnostic system for checking the function of pneumatic cylinders using acoustic emission. There are compared the records of the AE signal from the undamaged pneumatic cylinders and similar entries from cylinders containing artificial defects. Records of signals are monitored by modern analysers DAKEL IPL with full sampling of the signal. Based on the analysis of large data sets are selected suitable AE signal parameters, which can be used for more accurately diagnostics of condition of tested devices which could be used for constructing of analyser for testing of pneumatic devices.

Klíčová slova česky

akustická emise, signální, pneumatický válec, poškození

Klíčová slova anglicky

acoustic emission, signal, pneumatic valve, damage

Vydáno

13.06.2016

Nakladatel

German Society for NDT

Místo

Munchen, Germany

ISBN

978-3-940283-78-8

Kniha

19th WCNDT 2016 - World Conference on NDT

Číslo edice

první

Strany od–do

1–10

Počet stran

10

BIBTEX


@inproceedings{BUT127635,
  author="Pavel {Mazal} and František {Vlašic} and Houssam {Mahmoud},
  title="The Use of Acoustic Emission Method for Diagnosis of Damage of Pneumatic Cylinders",
  booktitle="19th WCNDT 2016 - World Conference on NDT",
  year="2016",
  month="June",
  pages="1--10",
  publisher="German Society for NDT",
  address="Munchen, Germany",
  isbn="978-3-940283-78-8"
}