Detail publikace

Měření obsahu vlhkosti jemných práškových materiálu pomoci IR spektroskopie.

SVĚRÁK, T. Baker, G. J. CH. SIKOROVÁ, K. KEJÍK, P. BULEJKO, P. KRIŠTOF, O.

Český název

Měření obsahu vlhkosti jemných práškových materiálu pomoci IR spektroskopie.

Anglický název

Progress of the IR measurement in the area of the fine particulate material water content

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus

Český abstrakt

Práce srovnává výsledky testu kontinuálního měření obsahu vlhkosti vápenného hydrátu v rámci provozních podmínek, kde byla měřena vlhkost pomoci IR spektroskopie a klasického způsob úbytku hmotnosti v sušicí komoře. Velké rozdíly, které oba systémy měření ukazují, jsou vysvětleny v souvislosti se změnami v provozních podmínkách měření.

Anglický abstrakt

The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus

Klíčová slova česky

obsah vlhkosti, jemné částice materiálu, infračervená spektra

Klíčová slova anglicky

moisture content, fine particulate material, infrared spectra

Rok RIV

2014

Vydáno

19.12.2014

Nakladatel

Institute of Research Engineers and Doctors,

Místo

USA

ISBN

978-1-63248-033-0

Kniha

Proceedings of the 2nd International Conference on Advances in Applied Science and Environmental Engineering

Strany od–do

20–23

Počet stran

4

BIBTEX


@inproceedings{BUT111745,
  author="Tomáš {Svěrák} and Kateřina {Mayerová} and Pavel {Kejík} and Pavel {Bulejko} and Ondřej {Krištof},
  title="Progress of the IR measurement in the area of the fine particulate material water content",
  booktitle="Proceedings of the 2nd International Conference on Advances in Applied Science and Environmental Engineering",
  year="2014",
  month="December",
  pages="20--23",
  publisher="Institute of Research Engineers and Doctors,",
  address="USA",