Detail publikace

SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION

HRNČÍŘOVÁ, M. ŠPILÁČEK, M. POSPÍŠIL, J.

Český název

SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION

Anglický název

Size analysis of solid particles at the experimental device for multi-stage biomass combustion

Typ

článek v časopise ve Scopus, Jsc

Jazyk

en

Originální abstrakt

This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.

Český abstrakt

This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.

Anglický abstrakt

This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.

Klíčová slova česky

solid, particles, biomass

Klíčová slova anglicky

solid, particles, biomass, laser diffraction, emission, biomass combustion, exhaust pipe

Rok RIV

2014

Vydáno

28.02.2014

Nakladatel

Czech Technical University in Prague

Místo

Prague

ISSN

1210-2709

Ročník

54

Číslo

1

Strany od–do

22–27

Počet stran

6

BIBTEX


@article{BUT107982,
  author="Michaela {Hrnčířová} and Michal {Špiláček} and Jiří {Pospíšil},
  title="Size analysis of solid particles at the experimental device for multi-stage biomass combustion",
  year="2014",
  volume="54",
  number="1",
  month="February",
  pages="22--27",
  publisher="Czech Technical University in Prague",
  address="Prague",
  issn="1210-2709"
}