Detail publikace

Vliv složení oceli na koeficient přestupu tepla při sekundárním chlazení u kontinuálního lití

KENNETH, B. MORAVEC, R. HORSKÝ, J. GUZEJ, M.

Český název

Vliv složení oceli na koeficient přestupu tepla při sekundárním chlazení u kontinuálního lití

Anglický název

The Effect of Steel Composition on the Interfacial Heat Transfer Coefficients for the Secondary Cooling Zones in a Continuous Caster

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

The numerical models of solidification are used in the process of steel continuous casting. The main effects on the precise function of this model have the following factors: casting speed, type of steel, the nozzles cooling effect etc. The company ArcelorMittal decided to develop its own model which utilizes measured heat transfer coefficients (HTC) for each nozzle configuration and all operating parameters that occur at the caster. Heat Transfer and Fluid Flow Laboratory from the Brno University of Technology developed its own methodology for measurement and software data processing to find out correct value of HTC for each type and position of the nozzles. These data are used as boundary conditions for the ArcelorMittal's model.

Český abstrakt

U kontinuálního lití ocelí se používají numerické modely tuhnutí. Na jejich správnou funkci mají vliv hl. tyto faktory: rychlost lití, druh oceli, chladící účinek trysek atd. Společnost ArcelorMittal se rozhodla vyvinout vlastní model, který využívá naměřené koeficienty přestupu tepla (HTC) pro každou konfiguraci trysek a všechny provozní parametry licí linky. Zjišťováním HTC pro daný typ a pozici trysek se zabývá Laboratoř přenosu tepla a proudění z univerzity VUT v Brně, která vyvinula svoji metodiku měření a softwarového zpracování naměřených dat. Tyto data jsou následně použita jako okrajové podmínky pro model společnosti ArcelorMittal.

Anglický abstrakt

The numerical models of solidification are used in the process of steel continuous casting. The main effects on the precise function of this model have the following factors: casting speed, type of steel, the nozzles cooling effect etc. The company ArcelorMittal decided to develop its own model which utilizes measured heat transfer coefficients (HTC) for each nozzle configuration and all operating parameters that occur at the caster. Heat Transfer and Fluid Flow Laboratory from the Brno University of Technology developed its own methodology for measurement and software data processing to find out correct value of HTC for each type and position of the nozzles. These data are used as boundary conditions for the ArcelorMittal's model.

Klíčová slova česky

Koeficient přestupu tepla, sekundární chlazení, kontinuální lití, intenzita chlazení

Klíčová slova anglicky

Heat transfer coefficient, secondary cooling, continuous casting, cooling intensity

Rok RIV

2014

Vydáno

05.05.2014

Nakladatel

AISTech 2014

Místo

Indianapolis

ISBN

9781935117421

ISSN

1551-6997

Kniha

AISTech 2014 Iron and Steel Technology Conference

Ročník

3

Číslo

1

Strany od–do

2873–2880

Počet stran

8

BIBTEX


@inproceedings{BUT107955,
  author="Kenneth {Blazek} and Jaroslav {Horský} and Michal {Guzej} and Rudolf {Moravec},
  title="The Effect of Steel Composition on the Interfacial Heat Transfer Coefficients for the Secondary Cooling Zones in a Continuous Caster",
  booktitle="AISTech 2014 Iron and Steel Technology Conference",
  year="2014",
  volume="3",
  number="1",
  month="May",
  pages="2873--2880",
  publisher="AISTech 2014",
  address="Indianapolis",
  isbn="9781935117421",
  issn="1551-6997"
}