Výpočtové modelování vlivu tvarových odchylek na kulové ploše keramické hlavice kyčelní endoprotézy
FUIS, V. KOUKAL, M. FLORIAN, Z. JANÍČEK, P.
Český název
Výpočtové modelování vlivu tvarových odchylek na kulové ploše keramické hlavice kyčelní endoprotézy
Anglický název
Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
en
Originální abstrakt
The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality loss is acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.
Český abstrakt
Příspěvek se zabývá výpočtovým modelování vlivu tvarových odchylek na kulové ploše keramické hlavice kyčelní endoprotézy na rozložení kontaktního tlaku a na velikost třecího momentu mezi komponentami.
Anglický abstrakt
The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality loss is acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.
Klíčová slova česky
totální náhrada kyčelní endoprotézy, tvarové odchylky, nekruhovitost, kontaktní tlak, třecí moment
Klíčová slova anglicky
total hip replacement, shape deviations, roundness, contact pressure, frictional moment
Rok RIV
2013
Vydáno
25.09.2013
Nakladatel
Springer
Místo
Seville
ISBN
978-3-319-00845-5
ISSN
1680-0737
Kniha
XI Mediterranean Conference on Medical and Biological Engineering and Computing 2013
Ročník
41
Číslo edice
Vol. 41
Strany od–do
89–92
Počet stran
4
BIBTEX
@inproceedings{BUT104713,
author="Vladimír {Fuis} and Milan {Koukal} and Zdeněk {Florian} and Přemysl {Janíček},
title="Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement",
booktitle="XI Mediterranean Conference on Medical and Biological Engineering and Computing 2013",
year="2013",
volume="41",
month="September",
pages="89--92",
publisher="Springer",
address="Seville",
isbn="978-3-319-00845-5",
issn="1680-0737"
}