Originální abstrakt
The goal of this project is to describe the secondary cooling system of DC caster in AMAG. The first stage is concentrated on monitoring of present situation. Realistic cooling conditions will be simulated in laboratory. Heat Transfer and Fluid Flow Laboratory have developed methodology of heat transfer measurement based on unsteady temperature measurement and data evaluation using the inverse task. Results contain information about surface temperature dependent heat flux (q) and heat transfer coefficient (HTC). Data format is suitable for using in numerical simulations.
Klíčová slova anglicky
Hliník, Přímé odlévání hliníku, Koeficient přestupu tepla, Inverzní úloha, Termočlánek
Vydáno
2013-12-02
Strany od–do
1–25
Počet stran
25
BIBTEX
@misc{BUT103861,
author="Jaroslav {Horský} and Michal {Guzej} and Petr {Kotrbáček}",
title="Verification Stand for ALU Plates - 1st task",
year="2013",
pages="1--25",
note="Summary research report"
}