Detail publikace

Detekce závady palivové pumpy založená na FFT zvlnění proudu a sledování magnetického pole

VEJLUPEK, J. GREPL, R. MATĚJÁSKO, M. ZOUHAR, F.

Český název

Detekce závady palivové pumpy založená na FFT zvlnění proudu a sledování magnetického pole

Anglický název

Automotive fuel pump fault detection based on current ripple FFT and changes in magnetic field

Typ

článek v časopise - ostatní, Jost

Jazyk

en

Originální abstrakt

This paper presents the approach for the testing of the automotive fuel pump with DC motor. Several faults such as pump jamming, incorrect soldering and/or damage to the commutator can occur due to incorrect manufacture processes. The proposed methods are based on current and magnetic field measurements and subsequent signal processing. The range checking, FFT analysis of the current ripples and change detection are combined to reach the correct and robust fault detection. During the test, the pump is optionally loaded using air suction applied to pump outlet. The implementation of developed algorithms suitable for the production line is also presented.

Český abstrakt

Tento článek popisuje nový přístup k testování a diagnostice automobilových nádržových modulů s DC motorem. Cílem je detekovat chyby, které mohli vzniknout v důsledku chyby ve výrobním procesu: zaseknutá pumpa, opačné zapojení napájecích kabelů, poškození motoru. Metody jsou založené na měření magnetického pole vně modulu a na FFT analýze zvlnění proudu. Kombinací více metod získáváme robusní postup uplatnitelný v průmyslu přímo v rámci výrobní linky.

Anglický abstrakt

This paper presents the approach for the testing of the automotive fuel pump with DC motor. Several faults such as pump jamming, incorrect soldering and/or damage to the commutator can occur due to incorrect manufacture processes. The proposed methods are based on current and magnetic field measurements and subsequent signal processing. The range checking, FFT analysis of the current ripples and change detection are combined to reach the correct and robust fault detection. During the test, the pump is optionally loaded using air suction applied to pump outlet. The implementation of developed algorithms suitable for the production line is also presented.

Klíčová slova anglicky

application of magnetic field sensor; automotive production; DC motor diagnosis; sensorless motion measurement;

Rok RIV

2013

Vydáno

04.10.2013

Nakladatel

North Atlantic University Union

ISSN

2074-1308

Ročník

2013

Číslo

3

Strany od–do

130–138

Počet stran

9

BIBTEX


@article{BUT102827,
  author="Josef {Vejlupek} and Robert {Grepl} and Michal {Matějásko} and František {Zouhar},
  title="Automotive fuel pump fault detection based on current ripple FFT and changes in magnetic field",
  year="2013",
  volume="2013",
  number="3",
  month="October",
  pages="130--138",
  publisher="North Atlantic University Union",
  issn="2074-1308"
}