Detail publikace
Měření tepelných toků v procesních zařízeních - případová studie
VONDÁL, J. HÁJEK, J.
Český název
Měření tepelných toků v procesních zařízeních - případová studie
Anglický název
Heat Flux Measurement Methods for Process Furnaces – a Case Study
Typ
článek v časopise - ostatní, Jost
Jazyk
en
Originální abstrakt
The distribution of heat loads to heat exchanging surfaces in process furnaces (fired heaters, boilers) is an important factor influencing efficiency of the process as well as lifetime of the unit. This work compares two heat flux measurement methods in a controlled environment of large-scale laboratory combustion facility. The experiment makes use of a low-NOx burner firing natural gas at 745 kW thermal duty. Heat fluxes are measured firstly by a water-cooled Schmidt-Boelter sensor (Hukseflux SBG01), which represents the typical approach applied in industrial practice. Second method is based on segmental design of water- cooled walls of the combustion chamber. The latter method provides total heat flux measurement on the process medium side and has several advantages over the standard method. This paper provides a comparison of heat flux distributions measured by the two methods as well as a quantitative analysis of the strong and weak points of both methods. Researchers and practitioners alike should find this paper helpful in interpretation of measured heat flux data.
Český abstrakt
Rozložení tepelného zatížení stěn v procesních pecích je důležitým paramterem ovlivňujícím účinnost a životnost zařízení. Tato práce porovnává dva přístupy k měření tepelných toků na spalovacím zařízení. Při testech byl využit nízkoemisní hořák na zemní plyn s výkonem 745 kW. Tepelné toky jsou měřeny vodou chlazenou sondou typu Schmidt-Boelter (Hukseflux SBG01), jež představuje typický přístup běžný v technické praxi. Dalším typem měření využívá segmentového rozdělení vodou chlazeného pláště komory. Tato metoda poskytuje údaje o celkovém předaném teple na straně procesního média a má několik předností ve srovnání se standardní metodou.
Anglický abstrakt
The distribution of heat loads to heat exchanging surfaces in process furnaces (fired heaters, boilers) is an important factor influencing efficiency of the process as well as lifetime of the unit. This work compares two heat flux measurement methods in a controlled environment of large-scale laboratory combustion facility. The experiment makes use of a low-NOx burner firing natural gas at 745 kW thermal duty. Heat fluxes are measured firstly by a water-cooled Schmidt-Boelter sensor (Hukseflux SBG01), which represents the typical approach applied in industrial practice. Second method is based on segmental design of water- cooled walls of the combustion chamber. The latter method provides total heat flux measurement on the process medium side and has several advantages over the standard method. This paper provides a comparison of heat flux distributions measured by the two methods as well as a quantitative analysis of the strong and weak points of both methods. Researchers and practitioners alike should find this paper helpful in interpretation of measured heat flux data.
Klíčová slova česky
CFd, vířivé proudění, spalování, vířič
Klíčová slova anglicky
CFD, Swirl flow, Combustion, Swirler
Rok RIV
2013
Vydáno
29.09.2013
Nakladatel
AIDIC Servizi S.r.l.
Místo
Milano, Italy
ISSN
1974-9791
Ročník
35
Číslo
1
Strany od–do
1153–1158
Počet stran
6
BIBTEX
@article{BUT102086,
author="Jiří {Vondál} and Jiří {Hájek},
title="Heat Flux Measurement Methods for Process Furnaces – a Case Study",
year="2013",
volume="35",
number="1",
month="September",
pages="1153--1158",
publisher="AIDIC Servizi S.r.l.",
address="Milano, Italy",
issn="1974-9791"
}