Detail publikace
Měření zbytkové napjatosti metodou uvolňování sloupku: Analýza kalibračních koeficientů pro metodu přírůstku deformace
CIVÍN, A. VLK, M.
Český název
Měření zbytkové napjatosti metodou uvolňování sloupku: Analýza kalibračních koeficientů pro metodu přírůstku deformace
Anglický název
Ring-Core Residual Stress Measurement: Analysis of Calibration Coefficients for Incremental Strain Method
Typ
článek v časopise - ostatní, Jost
Jazyk
en
Originální abstrakt
Correctly determined and properly used calibration coefficients for a residual stress measurement by ring-core method (RCM) are essential. Knowledge of their dependence on the disposition of residual state of stress cross the depth of metallic material gives results correspond of theirs appropriate application. In this article, incremental strain method (ISM) is used for determination of the calibration coefficients K1 and K2 under uniaxial and biaxial state of stress conditions. Finite element method (FEM) has been used in order to calculate relieved residual strains on the top of the core. Calculated calibration coefficients are plotted on graphs in dependence on the drilled depth and character of the residual stress state. Appropriate polynomial functions have been interposed by these points. We conclude that values of calibration coefficients K1 and K2 determined by the incremental strain method can be used only for homogenous residual states of stress. Examination of linearly varying state of stress indicates inaccurate results increasing with the depth of drilled groove.
Český abstrakt
Článek se zabývá analýzou kalibračních koeficientů pro pro vyhodnocení homogenního pole napjatosti po hloubce odvrtaného materiálu. Koeficienty jsou určeny pro metodu přírůstku deformace, pomocí které lze stanovyt velikosti a směry halvních zbytkových napětí.
Anglický abstrakt
Correctly determined and properly used calibration coefficients for a residual stress measurement by ring-core method (RCM) are essential. Knowledge of their dependence on the disposition of residual state of stress cross the depth of metallic material gives results correspond of theirs appropriate application. In this article, incremental strain method (ISM) is used for determination of the calibration coefficients K1 and K2 under uniaxial and biaxial state of stress conditions. Finite element method (FEM) has been used in order to calculate relieved residual strains on the top of the core. Calculated calibration coefficients are plotted on graphs in dependence on the drilled depth and character of the residual stress state. Appropriate polynomial functions have been interposed by these points. We conclude that values of calibration coefficients K1 and K2 determined by the incremental strain method can be used only for homogenous residual states of stress. Examination of linearly varying state of stress indicates inaccurate results increasing with the depth of drilled groove.
Klíčová slova česky
kalibrační koeficienty, metoda přírůstku deformace, zbytkové napětí, metoda uvolňování sloupku, tenzometrická růžice
Klíčová slova anglicky
calibration coefficient, incremental strain method, residual stress, ring-core method, strain gauge
Rok RIV
2011
Vydáno
31.01.2011
ISSN
1801-1217
Časopis
Bulletin of Applied Mechanics
Ročník
6
Číslo
24
Strany od–do
77–82
Počet stran
5
BIBTEX
@article{BUT50554,
author="Adam {Civín} and Miloš {Vlk},
title="Ring-Core Residual Stress Measurement: Analysis of Calibration Coefficients for Incremental Strain Method",
journal="Bulletin of Applied Mechanics",
year="2011",
volume="6",
number="24",
month="January",
pages="77--82",
issn="1801-1217"
}