Publication detail
Determination of Mechanical Properties of Spinal Segment after Implantation of DYNESYS Spinal Segment
NÁVRAT, T. FLORIAN, Z. CIENCIALA, J.
Czech title
Určování mechanických vlastností páteřního segmentu po aplikaci fixátoru DYNESYS
English title
Determination of Mechanical Properties of Spinal Segment after Implantation of DYNESYS Spinal Segment
Type
conference paper
Language
en
Original abstract
Within this work an initial study was conducted focusing on the comparison of mechanical properties of the undamaged spinal segment of the segment after decompression and that stabilized by the DYNESYS implants. The problem area was solved by means of experimental modelling applying the ZWICK testing machine where loading for several statuses of the spinal segment was simulated. While utilizing the capacities of the testing machine, a special device for the simulation of flexion-extension motion was constructed.
Czech abstract
V této práci byla provedena úvodní studie, jež si kladla za cíl srovnat mechanické vlastnosti páteřního segmentu neporušeného a po stabilizaci implantátem DYNESYS. Problematika byla řešena experimentálním modelováním s využitím zkušebního stroje ZWICK, na kterém byly simulovány zatížení pro několik stavů páteřního segmentu. Byl zkonstruován speciální přípravek pro simulaci flexního a extenzního pohybu při využití možností zkušebního stroje.
English abstract
Within this work an initial study was conducted focusing on the comparison of mechanical properties of the undamaged spinal segment of the segment after decompression and that stabilized by the DYNESYS implants. The problem area was solved by means of experimental modelling applying the ZWICK testing machine where loading for several statuses of the spinal segment was simulated. While utilizing the capacities of the testing machine, a special device for the simulation of flexion-extension motion was constructed.
Keywords in Czech
páteřní prvek, DYNESYS
Keywords in English
Spinal segment, DYNESYS
RIV year
2007
Released
09.07.2007
Publisher
Biomedical Engineering Society, World Association for Chinese Biomedical Engineers
Location
Bangkok, Thailand
ISBN
978-81-904262-8-2
Book
World Congress on Bioengineering 2007
Edition number
1
Pages count
4
BIBTEX
@inproceedings{BUT24045,
author="Tomáš {Návrat} and Zdeněk {Florian} and Jan {Cienciala},
title="Determination of Mechanical Properties of Spinal Segment after Implantation of DYNESYS Spinal Segment",
booktitle="World Congress on Bioengineering 2007",
year="2007",
month="July",
publisher="Biomedical Engineering Society, World Association for Chinese Biomedical Engineers",
address="Bangkok, Thailand",
isbn="978-81-904262-8-2"
}